Datasheet4U Logo Datasheet4U.com

AD8302 - RF/IF Gain and Phase Detector

General Description

The AD8302 is a fully

Key Features

  • Measures Gain/Loss and Phase up to 2.7 GHz Dual Demodulating Log Amps and Phase Detector Input Range.
  • 60 dBm to 0 dBm in a 50 ⍀ System Accurate Gain Measurement Scaling (30 mV/dB) Typical Nonlinearity < 0.5 dB Accurate Phase Measurement Scaling (10 mV/Degree) Typical Nonlinearity < 1 Degree Measurement/Controller/Level Comparator Modes Operates from Supply Voltages of 2.7 V.
  • 5.5 V Stable 1.8 V Reference Voltage Output Small Signal Envelope Bandwidth from DC to 30 MHz.

📥 Download Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
a FEATURES Measures Gain/Loss and Phase up to 2.7 GHz Dual Demodulating Log Amps and Phase Detector Input Range –60 dBm to 0 dBm in a 50 ⍀ System Accurate Gain Measurement Scaling (30 mV/dB) Typical Nonlinearity < 0.5 dB Accurate Phase Measurement Scaling (10 mV/Degree) Typical Nonlinearity < 1 Degree Measurement/Controller/Level Comparator Modes Operates from Supply Voltages of 2.7 V–5.5 V Stable 1.8 V Reference Voltage Output Small Signal Envelope Bandwidth from DC to 30 MHz APPLICATIONS RF/IF PA Linearization Precise RF Power Control Remote System Monitoring and Diagnostics Return Loss/VSWR Measurements Log Ratio Function for AC Signals LF–2.