900,000+ datasheet pdf search and download

Datasheet4U offers most rated semiconductors data sheet pdf






All Sensors

BLC-L30D Datasheet Preview

BLC-L30D Datasheet

Low Pressure Compact Sensors

No Preview Available !

BLC Series Low Pressure Compact Sensors
Features
• 0 to 1 inH2O to 0 to 30 inH2O and 15 PSIA Pressure Ranges
• uPower Low Supply Voltage (0.9V to 1.8V)
• 0.1% Linearity Typical
• Improved Front to Back Linearity
Less Position Sensitivity
• Improved Warm-Up Shift Distribution
• Parylene Coating Available Upon Request
Applications
• Medical Instrumentation
• Environmental Controls
• HVAC
• Portable / Hand Held Devices
General Description
The BLC Series Basic Low Pressure Compact Sensor is based on All Sensors’ CoBeam2 TM Technology. The device provides a high output
signal at a low operating voltage and reduces the overall supply voltage while maintaining comparable output levels to traditional
equivalent basic sensing elements. This lower supply voltage gives rise to improved warm-up shift while the CoBeam2 Technology itself
reduces package stress susceptibility resulting in improved overall long term stability. The technology also vastly improves position
sensitivity compared to conventional single die devices.
This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like. The output is also ratio-
metric to the supply voltage and is operable from 0.9 to 1.8 volts DC.
Standard Pressure Ranges
Device
BLC-L01D
BLC-L05D
BLC-L10D
BLC-L20D
BLC-L30D
BLC-015A
Operating Range
±1 inH2O (250 Pa)
±5 inH2O (1,250 Pa)
±10 inH2O (2,500 Pa)
±20 inH2O (5,000 Pa)
±30 inH2O (7,500 Pa)
0 to 15 PSIA (1 barA)
Proof Pressure
100 inH2O (25 KPa)
200 inH2O (50 KPa)
200 inH2O (50 KPa)
200 inH2O (50 KPa)
200 inH2O (50 KPa)
60 PSI (4 barA)
Burst Pressure
150 inH2O (37 KPa)
300 inH2O (75 KPa)
300 inH2O (75 KPa)
500 inH2O (125 KPa)
800 inH2O (200 KPa)
120 PSI (8 barA)
Pressure Sensor Maximum Ratings
Supply Voltage (Vs)
Common Mode Pressure
Lead Temperature (soldering 2-4 sec.)
3 Vdc
5 psig
270 °C
Environmental Specifications
Temperature Ranges
Operating
Storage
Humidity Limits
-25 to 85 °C
-40 to 125 °C
0 to 95% RH
(non condensing)
All Sensors
DS-0353 Rev F
Page 1




All Sensors

BLC-L30D Datasheet Preview

BLC-L30D Datasheet

Low Pressure Compact Sensors

No Preview Available !

Performance Characteristics for BLC Series
All parameters are measured at 1.8V excitation and room temperature unless otherwise specified. Pressure measurements are with positive pressure applied
to Port B (the only port for the single port configuration.)
Parameter
Min Typ Max Units Notes
Output Span (FSS)
4
L01D
L05D
L10D
L20D
L30D
015A
4.5 8.0 11.5 mV
13.5 24.0 34.5 mV
18.0 32.0 46.0 mV
22.0 38.0 55.0 mV
25.0 42.0 60.0 mV
70.0 95.0 120.0 mV
Offset Voltage
-
L01D, L05D, L10D, L20D, L30D (@ Zero Diff. Pressure) -
-
±10.0
mV
015A (@ 0 PSIA)
- - ±10.0 mV
Offset Temperature Shift (0°C-70°C)
-
±30.0
-
μ V/°C
1
Offset Warm-up Shift
- ±30.0 -
μ V 2, 6
Offset Position Sensitivity (1g)
- ±20.0 -
μ V -
Linearity, Hysteresis Error
-
0.10
±0.50
%FSS
3
Response Time (10% to 90% Pressure Response)
-
100
-
μ S -
Front to Back Linearity
-
0.25
-
%FSS
5
Temperature Effect on Resistance (0°C-70°C)
-
2800
-
ppm/°C
-
Temperature Effect on Span (0°C-70°C)
-
-2000
-
ppm/°C
-
Input Resistance
- 3.4 - k Ω -
Output Resistance
- 3.4 - k Ω -
Specification Notes
note 1: Shift is relative to 25°C.
note 2: Shift is within the first hour of excitation applied to the device.
note 3: Measured at one-half full scale rated pressure using best straight line curve fit.
note 4: The span is the algebraic difference between full scale output voltage and the offset voltage.
note 5: Front-Back Linerity computed as:
Lin FB
Span PortB
1100%
SpanPortA
note 6: Typical warm up of characteristics as shown below.
BLC Warmup Shift (Typical)
0.050
0.030
0.010
0
-0.010
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
1
-0.030
-0.050
Hrs
Soldering Recommendations
1) Solder parts as a second operation only.
2) Post reflow, wait for 36 hrs before performing any calibration operations.
3) Perform spot cleaning as necessary only by hand. DO NOT wash or submerge device in cleaning liquid.
BLC Series Low Pressure Compact Sensors
Page 2


Part Number BLC-L30D
Description Low Pressure Compact Sensors
Maker All Sensors
Total Page 8 Pages
PDF Download

BLC-L30D Datasheet PDF

View PDF for Mobile








Similar Datasheet

1 BLC-L30D Low Pressure Compact Sensors
All Sensors





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z

Site map

Webmaste! click here

Contact us

Buy Components

Privacy Policy