Emerson
Emerson


IBC32AEN4896-EKJ

DC-DC / Intermediate Bus Converter



No Preview Available !

IBC32AEN4896-EKJ pdf
Embedded Power for
Business-Critical Continuity
IBC32
Eighth-Brick
Series
Fixed Ratio
2nd Generation IBC
Total Power: 300W
Input Voltage: 38 - 55 Vdc
Rev.05.12.08
eighth_brick_300w_ibc32
1 of 4
Special Features
• 48 V input with isolated 9.6 V
output
• Ultra-high efficiency, 97%
• Unprecedented usable
output power levels
• High power density
open-frame technology
• Wide operating ambient
temperature range
• Industry standard eighth-
brick footprint and pinout
• Low profile, 0.48" (12.2 mm)
• Meets basic insulation
requirements of EN60950-1
• Remote ON/OFF and
overtemperature protection
• RoHS compliant
• 2 year warranty
Safety
UL/cUL 60950-1, 1st Edition
EN 60950-1 VDE
Electrical Specifications
Output
Line regulation:
Low line to high line
Load regulation
Full load to min. load
Total error band (including set- Vin = 38 V to 55 V
point, line, load and temperature)
See table
See table
7.0 - 11.0 Vdc
Minimum load
Overshoot
Undershoot
Ripple and noise
5 - 20 MHz
At turn on and turn-off
(See note 2)
0A
None
None
100 mV pk-pk typ.
30 mV rms typ.
Input
Input voltage range
Input current
Input current (max.)
Input reflected ripple
(See note 4)
38 - 55 Vdc
Remote OFF
(See note 1)
550 mA (pk-pk)
200 MA rms
7 mA typ.
8.6 A max. @ lo max.
and Vin = min. rated
Remote ON/Off
Logic compatiblity
On
OFF
Undervoltage lockout
Startup time (see note 3)
Power-up
Power-down
Power-up
Remote ON/OFF
(see note 6)
Open collector ref. to- input
>2.4 Vdc
<0.8 Vdc
35 V
33.5 V
12 ms
1 ms



No Preview Available !

IBC32AEN4896-EKJ pdf
Embedded Power for
Business-Critical Continuity
All specifications are typical at nominal input, full load at 25° C unless otherwise stated.
EMC Charateristics
Immunity:
ESD air enclosure
Input transients:
EN61000-4-2 8 kV, 6 kV
(Air contact)
Input voltage
>58 V
>60 V
>62 V
Duration before shutdown
2 seconds
1 second
0 seconds
General Specifications
Efficiency
Basic insulation
Input/output
Switching frequency Fixed
Approvals and
standards (see note 5)
97%
2250 Vdc
350 kHz typ.
EN60950-1 VDE
UL/cUL60950-1
Material flammability
Weight
MTBF
Representative model:
Telcordia Tech SR-332
48 Vin, 40 °C, 50% load
ground benign
UL94V-0
37 g (1.31 oz)
2,100,000 hours
Rev.05.12.08
eighth_brick_300w_ibc32
2 of 4
Environmental Specifications
Thermal
Operating ambient, -40 °C to +85 °C
performance temperature
Non-operating
-55 °C to +125 °C
Protection
Short-circuit Hiccup
Overvoltage (See note 9)
Thermal
Non-latching
125 °C hot spot
Ordering Information
Output
Power
(Max.)
Input
Voltage
300 W
38 - 55 Vdc
Output
Voltage
9.6 V
Output
Current
(Min.)
0A
Output Current Efficiency
(Max.)
(Typ.)
32 A 97%
Set Point
Accuracy %
---
Regulation2
Line %
ΔVin/5
Load
2.3%
Model Number
IBC32AEN4896J
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
Part Number System with Options
Product Family
IBC
Rated Output
Current
32A
Form Factor
E
IBC Intermediate 32 A = 32
Bus Converter Amps at 48 V
2nd Generation
E = Eighth-
Brick
Input Voltage Type
N
Input
Voltage
48
Output
Voltage
96 -
Remote
ON/OFF Logic
R
Package, Body
Height
E
Pin Length
Options
N
RoHS
Compliance (10)
J
T = Narrow Input
Fixed Ratio
S = Narrow Input
Semi-reguated
N = Narrow Telecom
Fixed Ratio
W = Wide Telecom
Semi-reguated
48 = 48 V 96 = 9.6 V
Blank =
Positive
R = Negative
(See Note 6)
E = Open-
frame, 0.48 in
(12.2 mm)
Blank = 0.188 ”
(4.78 mm)
N = 0.145 ”
(3.68 mm)
K = 0.110 ”
(2.79 mm)
J = Pb-free
(RoHS 6/6
compliant)
Notes
1 Recommended input fusing is a 20 A HRC 250 V rated fuse.
2 Measured with external filter. See Application Note 208 for details.
3 Start-up into resistive load.
4 Peak to peak measured without external Pi filter. Significant reduction
possible with external filter. See Application Note 208 for details.
5 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
6 Active-low remote ON/OFF option is also available. Please add the suffix ‘-R’
to the part number, e.g. IBC32AEN4896-REJ.
7 Maximum output power at maximum input voltage.
8 Efficiency at 100% maximum output voltage.
9 After an input overvoltage latch off, the input voltage must be returned to 55
V or lower for unit to restart.
10 TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special
request, please contact your local sales representative for details.



Part Number IBC32AEN4896-EKJ
Description DC-DC / Intermediate Bus Converter
Maker Emerson - Emerson
Total Page 3 Pages
PDF Download
IBC32AEN4896-EKJ pdf
Download PDF File
IBC32AEN4896-EKJ pdf
View for Mobile




Featured Datasheets

Part Number Description Manufacturers PDF
IBC32AEN4896-EJ DC-DC / Intermediate Bus Converter IBC32AEN4896-EJ
Emerson
PDF
IBC32AEN4896-EKJ DC-DC / Intermediate Bus Converter IBC32AEN4896-EKJ
Emerson
PDF
IBC32AEN4896-ENJ DC-DC / Intermediate Bus Converter IBC32AEN4896-ENJ
Emerson
PDF


Part Number Start With

0  1  2  3  4  5  6  7  8  9  A  B  C  D  E  F  G  H  I  J  K  L  M  N  O  P  Q  R  S  T  U  V  W  X  Y  Z

site map

webmaste! click here

contact us

Buy Components