http://www.www.datasheet4u.com

900,000+ Datasheet PDF Search and Download

Datasheet4U offers most rated semiconductors datasheets pdf




NAIS
NAIS


A-TB72

Time Switches



No Preview Available !

A-TB72 pdf
A-TB72 FLAT
TIME SWITCHES
A-TB72·72Q
72
2.835
72
2.835
Flush mounting type
75.2
2.961
90
3.543
Part names
Manural switch
• Auto and manual modes are selectable
for control.
Power status indicator: quartz
power-failure compensation type.
Frequency switchable: AC motor types.
Easy-to-read.
Directly read-
able clock.
• Present time is
trimmable every
1 minute.
Setting elements integrated at 15
minute intervals throughout the clock
circumference.
• Load can be turned on and off every 15 minutes
(maximum 48 ON and OFF actions per day),
allowing minute daily time control.
ON settings are colored
on the dial.
• Operation setting times are found
at a glance with red indicator.
Surface mounting type
Features
mm inch
Space-saving.
Depth in the box is less
than 21.7mm .854inch.
(including the panel thickness.)
Quick
mountable.
1. DIN72 size smart time switch
Flush mounting type is as thin as 32mm
1.260inch and depth in the box is less
than 21.7mm .854inch.
2. Easy to read directly readable
clock.
3. Load can be turned on and off
every 15 minutes with the 96 setting
elements.
4. Quartz power-failure compensation
type commonly usable over 100 to
240V AC.
Power supply Load
terminals
terminals
DIN rail mounting possible
Product types omType
t4u.cAC motor type
heeQuartz power-failure compensation type
Rated operating voltage
100V AC
110V AC
120V AC
200V AC
220V AC
240V AC
100 to 240V AC
Flush mounting type
A-TB72-D-HR1A-100V
A-TB72-D-HR1A-110V
A-TB72-D-HR1A-120V
A-TB72-D-HR1A-200V
A-TB72-D-HR1A-220V
A-TB72-D-HR1A-240V
A-TB72-Q-HR1A-ACF
w.datas³ LVWKHJOREDOQDPHRI0DWVXVKLWD(OHFWULF:RUNV´
ww ZZZEHOOHOHFWULFDOFRPDX
Surface mounting type
A-TB72-DD-HR1C-100V
A-TB72-DD-HR1C-110V
A-TB72-DD-HR1C-120V
A-TB72-DD-HR1C-200V
A-TB72-DD-HR1C-220V
A-TB72-DD-HR1C-240V
A-TB72-QD-HR1C-ACF




No Preview Available !

A-TB72 pdf
Specifications
Types
Drive system
Voltage
Rating
Time accuracy
Contact
specifications
Life
Frequency
Power consumption
Circuit
Load
Manual ON/AUTO
Capacity
(Resistive load)
System
Minimum unit
Setting
Ninimum range
No. of setting
Power failure compensation
Clock accuracy
Contact arrangement
Contact type
Mechanical life (contact)
Electrical life (at rated load)
Allowable operating voltage range
Insulation resistance (initial)
Electrical
characteristics
Dielectric strength (initial)
Surge resistance
Noise resistance
Temperature rise
Malfunctional vibration
Mechanical
Destructive vibration
characteristics Malfunctional shock
Destructive shock
Ambient
conditions
Ambient operating temperature
Ambient operating humidity
Weight ( ) denotes Surface mounting type
Note) Protective cover is provided on A-TB72.
AC motor type
Quartz power-failure compensation quartz motor type
100V AC, 110V AC, 120V AC
200V AC, 220V AC, 240V AC
100 to 240V AC
50/60Hz (Switchable)
50/60Hz (Common)
1.5W or less
1W or less
Input/output separate circuit
Manual switch provided
15A 250V AC
Built-in setting element swing type
15-minute intervals
15 minutes
Max. 48 (ON/OFF)
— 200 hours or more (at 25˚C)
Synchronous with power supply frequency
Monthly error: Within ±15 seconds (at 25˚C)
C
Solder/tab common terminal: Flush mounting type, Crimp terminal or bare wires: Surface mounting type
5,000,000 times or more
20,000 times or more (ON/OFF)
85 to 115% of rated voltage
80 to 110% of rated voltage
More than 100Mbetween contacts (at 500V DC megger)
Between charged and uncharged sections: 1,500V AC/1 min.
Between contacts
: 1,000V AC/1 min.
Surge voltage 7,000V (±1.2×50µsec. one time)
Noise simulator 2,000V
Noise simulator 1,000V
60˚C or less (at 25˚C)
16.7Hz (amplitude: 4.0mm) for 1 hour in each vertical, horizontal and lateral direction
5G or more, 4 times in each vertical, horizontal and lateral direction
–10˚
120g 4.23oz (190g 6.70oz)
˚C +14˚F to +122˚F
45 to 85%
100g 3.53oz (170g 6.00oz)
Dimensions
• Flush mounting type
Manual
switch
Quartz power-failure compensation:
Present Dial with built-in Power supply indicator
time setting elements AC motor type: Hz selection
ON-OFF
position
???
???
72 75.2
2.835 2.961
(???)
Time setting Setting element
67
2.638
27.2
5.5 1.071
32
1.260
39.2
1.543
.217
• Surface mounting type
75.2
2.961
(???)
72
2.835
90
3.543
mm inch
(42.5)
(1.673)
90±0.2
3.543±.008
OFF state
ON state
37.5
1.476
44
1.732
65±0.2
2.559±.008
3-M4 screw hole
3-M.157
(or φ 4.2±0.1 hole)
(or φ .165±.004 hole)
Terminal layouts and Wiring diagrams
• Flush mounting type
(1 Form A)
• Surface mounting type
(1 Form C)
S1
S2 L2
L1
NC
COM
S1 S2
NO
Rated operating
voltage
Load
Rated operating
voltage
Load
• Panel cutout dimensions
(Note) 82 3.228
or more
(Note) 82 3.228
or more
Panel thickness: 1.0 to 4.5mm .039 to .177inch
(Note) Minimum pitch for close mounting
³ LVWKHJOREDOQDPHRI0DWVXVKLWD(OHFWULF:RUNV´
 ZZZEHOOHOHFWULFDOFRPDX



Part Number A-TB72
Description Time Switches
Maker NAIS - NAIS
Total Page 3 Pages
PDF Download
A-TB72 pdf
Download PDF File
A-TB72 pdf
View for Mobile




Featured Datasheets

Part Number Description Manufacturers PDF
A-TB72 Time Switches A-TB72
NAIS
PDF
A-TB72Q Time Switches A-TB72Q
NAIS
PDF


Part Number Start With

0  1  2  3  4  5  6  7  8  9  A  B  C  D  E  F  G  H  I  J  K  L  M  N  O  P  Q  R  S  T  U  V  W  X  Y  Z

site map

webmaste! click here

contact us

Buy Components