http://www.Datasheet4U.com


60EPF02 Datasheet
FAST SOFT RECOVERY RECTIFIER DIODE

No Preview Available !

60EPF02 pdf
Download PDF File

www.DataSheet4U.com
FAST SOFT RECOVERY
RECTIFIER DIODE
Description/Features
The 60EPF.. & 60CPF.. fast soft recovery QUIETIR
rectifier series has been optimized for combined short
reverse recovery time and low forward voltage drop.
The glass passivation ensures stable reliable
operation in the most severe temperature and power
cycling conditions.
Typical applications are both:
Output rectification and freewheeling in
inverters, choppers and converters
and input rectifications where severe
restrictions on conducted EMI should be met.
Bulletin I2113 rev. D 04/99
QUIETIR Series
60EPF.. 60CPF..
VF < 1.1V @ 30A
trr = 70ns
VRRM 200 to 600V
Major Ratings and Characteristics
Characteristics
60EPF.. Units
60CPF..
IF(AV) Sinusoidalwaveform
VRRM
IFSM
VF @ 30 A, TJ = 25°C
trr @ 1A,100A/µs
60
200 to 600
830
1.1
70
A
V
A
V
ns
TJ
- 40 to 150
°C
Package Outline
60CPF..
60EPF..
TO-247AC (Modified)
1


60EPF02 Datasheet
FAST SOFT RECOVERY RECTIFIER DIODE

No Preview Available !

60EPF02 pdf
Download PDF File

www.DataSheet4U.com
60EPF.. 60CPF.. QUIETIR Series
Bulletin I2113 rev. D 04/99
Voltage Ratings
Part Number
60EPF02, 60CPF02
60EPF04, 60CPF04
60EPF06, 60CPF06
VRRM , maximum
peak reverse voltage
V
200
400
600
VRSM , maximum non repetitive
peak reverse voltage
V
300
500
700
IRRM
150°C
mA
5
Absolute Maximum Ratings
Parameters
IF(AV) Max.AverageForwardCurrent
IFSM Max.PeakOneCycleNon-Repetitive
SurgeCurrent
I2t Max. I2t for fusing
I2t Max. I2t for fusing
60.PF..
60
700
830
2450
3460
34600
Units
A
A
A2s
A2s
Conditions
@ TC=106°C,180°conductionhalfsinewave
10msSinepulse,ratedVRRMapplied
10msSine pulse,novoltagereapplied
10msSinepulse,ratedVRRMapplied
10msSinepulse,novoltagereapplied
t = 0.1 to 10ms, no voltage reapplied
Electrical Specifications
Parameters
VFM Max. Forward Voltage Drop
rt Forward slope resistance
VF(TO) Threshold voltage
IRM Max. Reverse Leakage Current
60.PF..
1.3
5.0
0.88
0.1
5.0
Units
V
m
V
mA
Conditions
@ 60A, TJ = 25°C
TJ = 150°C
TJ = 25 °C
TJ = 150 °C
VR = rated VRRM
Typical Recovery Characteristics
Parameters
trr Reverse Recovery Time
Irr Reverse Recovery Current
Qrr Reverse Recovery Charge
S Snap Factor
tb/ta
60.PF..
180
3.4
0.5
0.5
Units
Conditions
ns IF @ 60Apk
A @ 25A/ µs
µC @ 25°C
typical
Ifm
dir
dt
trr
ta tb
Qrr
t
Irm (REC)
2 www.irf.com


60EPF02 Datasheet
FAST SOFT RECOVERY RECTIFIER DIODE

No Preview Available !

60EPF02 pdf
Download PDF File

www.DataSheet4U.com
60EPF.. 60CPF.. QUIETIR Series
Bulletin I2113 rev. D 04/99
Thermal-Mechanical Specifications
Parameters
TJ Max.JunctionTemperatureRange
Tstg Max.StorageTemperatureRange
RthJC Max.ThermalResistanceJunction
toCase
RthJA Max.ThermalResistanceJunction
to Ambient
RthCS TypicalThermalResistance,Caseto
Heatsink
wt ApproximateWeight
T MountingTorque
Min.
Max.
Case Style
60.PF.. Units
-40to150 °C
-40to150 °C
0.4 °C/W
40 °C/W
0.2 °C/W
6(0.21) g(oz.)
6(5) Kg-cm
12(10) (Ibf-in)
TO-247AC
Conditions
DCoperation
Mountingsurface,smoothandgreased
JEDEC(Modified)
150
60.PF.. Series
140 R thJC (DC) = 0.4 K/W
130
Conduction Angle
120
110
100
90
0
90°
60°
30°
120°
180°
10 20 30 40 50 60 70
Average Forward Current (A)
Fig. 1 - Current Rating Characteristics
90
180°
80 120°
90°
70 60°
30°
60
RMS Limit
50
40
30 Conduction Angle
20
60.PF.. Series
10 TJ = 150°C
0
0 10 20 30 40 50 60 70
Average Forward Current (A)
Fig. 3 - Forward Power Loss Characteristics
www.irf.com
150
60.PF.. Series
140 R thJC (DC) = 0.4 K/W
130
Conduction Period
120
110
100
90
0
60°
30° 90°
120°
180°
DC
20 40 60 80 100
Average Forward Current (A)
Fig. 2 - Current Rating Characteristics
140
DC
120
180°
120°
90°
100 60°
30°
80
60 RMS Limit
40 Conduction Period
20
60.PF.. Series
T J = 150°C
0
0 20 40 60 80 100
Average Forward Current (A)
Fig. 4 - Forward Power Loss Characteristics
3


60EPF02 Datasheet
FAST SOFT RECOVERY RECTIFIER DIODE

No Preview Available !

60EPF02 pdf
Download PDF File

www.DataSheet4U.com
60EPF.. 60CPF.. QUIETIR Series
Bulletin I2113 rev. D 04/99
800
At Any Rated Load Condition And With
Rated V RRM Applied Following Surge.
700 Initial T J= 175°C
@ 60 Hz 0.0083 s
@ 50 Hz 0.0100 s
600
500
400
300
60.PF.. Series
200
1
10 100
Number Of Equal Amplitude Half Cycle Current Pulses (N)
Fig. 5 - Maximum Non-Repetitive Surge Current
1000
TJ= 150°C
100
900
Maximum Non Repetitive Surge Current
800 Versus Pulse Train Duration.
Initial T J = 195°C
700 No Voltage Reapplied
Rated V RRM Reapplied
600
500
400
300
200 60.PF.. Series
100
0.01
0.1
1
Pulse Train Duration (s)
Fig. 6 - Maximum Non-Repetitive Surge Current
TJ= 25°C
10
60.PF.. Series
1
0 0.5 1 1.5 2 2.5 3 3.5 4
Instantaneous Forward Voltage (V)
Fig. 7 - Forward Voltage Drop Characteristics
0.2
0.15
0.1
IFM = 60 A
30 A
10 A
5A
0.45
0.4
0.35
0.3
0.25
0.2
I FM = 60 A
30 A
10 A
5A
60.PF.. Series
TJ = 25 °C
0.05
0 40 80
1A
120 160 200
Rate Of Fall Of Forward Current - di/dt (A/µs)
Fig. 8 - Recovery Time Characteristics, TJ = 25°C
0.15 60.PF.. Series
1A
T J = 150 °C
0.1
10 20 30 40 50 60 70 80 90 100
Rate Of Fall Of Forward Current - di/dt (A/µs)
Fig. 9 - Recovery Time Characteristics, TJ = 150°C
4 www.irf.com


60EPF02 Datasheet
FAST SOFT RECOVERY RECTIFIER DIODE

No Preview Available !

60EPF02 pdf
Download PDF File

www.DataSheet4U.com
4
60.PF.. Series
T J = 25 °C
3
I FM = 60 A
30 A
2
10 A
1 5A
1A
0
0 40 80 120 160 200
Rate Of Fall Of Forward Current - di/dt (A/µs)
Fig. 10 - Recovery Charge Characteristics, TJ = 25°C
25
60.PF.. Series
20 TJ = 25 °C
I FM = 60 A
30 A
15
10 A
10
5A
5 1A
0
0 40 80 120 160 200
Rate Of Fall Of Forward Current - di/dt (A/µs)
Fig. 12 - Recovery Current Characteristics, TJ = 25°C
1
D = 0.50
D = 0.33
D = 0.25
0.1 D = 0.17
D = 0.08
Single Pulse
60EPF.. 60CPF.. QUIETIR Series
Bulletin I2113 rev. D 04/99
5
60.PF.. Series
4 TJ = 150 °C
I FM = 60 A
30 A
3
10 A
2
5A
1
1A
0
10 20 30 40 50 60 70 80 90 100
Rate Of Fall Of Forward Current - di/dt (A/µs)
Fig. 11 - Recovery Charge Characteristics, TJ = 150°C
25
60.PF.. Series
20 TJ = 150 °C
I FM = 60 A
15 30 A
10 A
10 5 A
5 1A
0
10 20 30 40 50 60 70 80 90 100
Rate Of Fall Of Forward Current - di/dt (A/µs)
Fig. 13 - Recovery Current Characteristics, TJ = 150°C
Steady State Value
(DC Operation)
60.PF.. Series
0.01
0. 001
www.irf.com
0.01
0.1
1
Square Wave Pulse Duration (s)
Fig. 14 - Thermal Impedance ZthJCCharacteristics
10
5


60EPF02 datasheets pdf
Total : 8 Pages
Download Full PDF File