Part Number |
SXE15 |
|
Manufacturer |
Artesyn Technologies |
|
Semiconductor DataSheet |
|
DataSheet View |
|
SXE15 Single Series | 10.8 to 15W DC/DC High Efficiency DC/DC Converters
SXE15 48V SERIES
Single output
High efficiency topology, 87% typical at 5V Wide operating temperature, up to and exceeding +70˚C (natural convection) 90% to 110% output trim No minimum load Overvoltage protection Remote on/off Approvals to EN60950 and UL/cUL1950 Complies with ETS 300 019-1-3/2-3 Complies with ETS 300 132-2 (input voltage and current requirements) Complies with ETS 300 386-1
The SXE15 is a new high efficiency open frame isolated 15 Watt converter series in an industry standard footprint. The first five models in the series feature an input voltage range of 33 to 75VDC and are available in output voltages of 12V, 5V, 3.3V, 2.5V and 1.8V. The output voltage on each model is adjustable from 90% to 110% of the nominal value. Typical efficiencies are 85% for 12V, 87% for the 5V, 86% for the 3.3V, 85% for the 2.5V and 12V and 83% for the 1.8V version. The SXE15 series has a remote on/off capability, with active 'HI' and active 'LO' options available. Overcurrent and
[ 2 YEAR WARRANTY ]
overvoltage protection features are included as standard. With full international safety approval including EN60950 and cUL1950, the SXE15 reduces compliance costs and time to market.
TÜV
1
File Name: lf_sxe15s.pdf Rev: 09 Sept 2005
SXE15 Single Series | SXA10 Series15W15W DC/DC 10.8 to | DC/DC High Efficiency DC/DC Converters
Stresses in excess of the maximum ratings can cause permanent damage to the device. Operation of the device is not implied at these or any other conditions in excess of those given in the specification. Exposure to absolute maximum ratings can adversely affect device reliability. Absolute Maximum Ratings Characteristic Input voltage - continuous Input voltage - peak/surge Operating temperature Symbol Vin (cont) Vsurge Top Tstorage Pout (max) Pout (max) Pout (max) Pout (max) Min -0.3 -0.3 -40 Typ Max 75 80 115 Units V DC V DC ºC Notes and Conditions Vin(+) - Vin(-) 2s max, non-repetitive Measured at thermal reference points, see Note 1
Storage temperature Output power (1.8V) Output power (2.5V) Output power (3.3V) Output power (5V)
-40
120 10.8 15 15 15
ºC W W W W
All specifications are typical at nominal input Vin = 48V, full load under any resistive load combination at 25ºC unless otherwise stated. Input Characteristics Characteristic Input voltage - operating Input current - no load Input current - Quiescent Input voltage variation Inrush current (i2t) Inrush current ratio Input ripple rejection Input fuse Symbol Vin (oper) lin lin (off) dv/dt linrush It/Im 300 19.5 45 2 dB A Min 33 Typ 33 28 20 Max 75 35 25 5 Units V DC mADC mADC V/ms µA2s Vin (min) - Vin (max), enabled Converter disabled Complies with ETS300 132 Part 4.4 Complies with ETS300 132 Part 4.7, with recommended LISN Complies with ETS300 132 Part 4.7, with recommended LISN Frequency <1 kHz Slowblow/Antisurge HRC recommended, 200V rating Notes and Conditions
Turn On/Off Characteristic Input voltage - turn on Input voltage - turn off Hysteresis Turn on delay - enabled, then power applied Symbol Vin (on) Vin (off) Tdelay (power) Min 30 27 Typ 33 30 3 1.5 Max 36 33 4 Units V DC V DC V DC msec With the enable signal asserted, this is the time from when the input voltage reaches the minimum specified operating voltage until the output voltage is within the total regulation band Vin = Vin (nom), then enabled. This is the time taken until the output voltage is within the total error band From 10% to 90%; full resistive load, no external capacitance Notes and Conditions
Turn on delay - power applied, then enabled
Tdelay (enable)
2.5
4
msec
Rise time
Trise
0.6
1
msec
File Name: lf_sxe15s.pdf Rev: 09 Sept 2005
2
SXE15 Single Series | 10.8 to 15W DC/DC High Efficiency DC/DC Converters
Signal Electrical Interface Characteristic - Signal Name Symbol At remote/control ON/OFF pin Open collector or equivalent compatible Control pin open circuit voltage Vih High level input current Iih Min Typ Max Units Notes and Conditions See Notes 2 and 3 See Application Note 116 for Remote On/Off detail Iih = 0 µA; open circuit voltage Current flowing into control pin when pin is pulled high (max. at Vih = 75V) Acceptable leakage current from signal pin into the open collector driver (neg = from converter) Converter guaranteed off when control pin is less than Vil (max) Vil = 0.4 V ViI = 0.0 V
12
13 10
V µA
Acceptable high level leakage current Low level input voltage
Iih (leakage)
-50
µA
ViI
0
1.2
V
Low level input current Low level input current
IiI Iil (max)
-1.4 -1.5
mA mA
Reliability and Service Life Characteristic Mean time between failure Symbol MTBF Min 600,000 Typ Max Units Hours Notes and Conditions MIL-HDBK-217F, Vin = Vin (nom); Iout = Iout (max); ambient 25ºC; ground benign environment per Bellcore TR-NWT-000332 Issue 3, ground benign, temp. = 40ºC, Vin = Vin (nom), Iout = Iout (max) Demonstrated.
Mean time between failure
MTBF
1,500,000
Hours
Mean time between failure Expected service life
MTBF
1,790,000
Hours Years
Isolation Characteristic Input to output test voltage Input to output capacitance Input to output resistance Input to output insulation system 100 Operational 1000 Symbol Min Typ Max 1500 Units V DC pF MΩ Measured with 500 V DC Notes and Conditions Test duration 1s
3
www.artesyn.com
File Name: lf_sxe15s.pdf Rev: 09 Sept 2005
SXA10 to | DC/DC SXE15 Single Series | 10.8Series15W15W DC/DC
High Efficiency DC/DC Converters
Other Specifications
Characteristic Switching frequency Weight Symbol Fsw Min Typ 265 12 Max Units kHz g Notes and Conditions Fixed frequency (all models)
Environmental Specifications
Characteristic Thermal performance 1V8 and 2V5 models 3V5 and 5V models Type Air temperature Parameter Low High Change Symbol Min Typ Max Units Notes and Conditions
-40 -40 Reference IEC 68-2-1 IEC 68-2-2 IEC 68-2-14
70 65 Test Level
ºC ºC
See Notes 1, 4 and individual derating curves Notes and Conditions All characteristics and parameters extracted from ETS 300 019 classes 3.1, 3.2, 3.3, 3.4 and 3.5 Tmax. = +70ºC for T3.4
-40ºC +70ºC -40ºC to +70ºC
Relative humidity
Low High Condensation
IEC 68-2-56 IEC 68-2-30
10% 100% 90 to 100% 5-9Hz 5mm/s 9-200Hz 1g 10g
Vibration IEC Class 3M5
Freq. velocity IEC 68-2-6 Freq. acceleration IEC 68-2-6 Acceleration IEC 68-2-29
Shock IEC Class 3M5
Referenced ETSI standards: ETS 300 019: Environmental conditions and environmental tests for telecommunications equipment ETS 300 019: Part 1-3 (1997) Classification of environmental conditions stationary use at weather protected locations ETS 300 019: Part 2-3 (1997) Specification of environmental tests stationary use at weather protected locations
EMC Electromagnetic Compatibility
Phenomenon Immunity: ESD Enclosure EN61000-4-2 6kV contact 8kV air 2kV 4kV 1kV 2kV 10V/m 10V 10V As per ETS 300 386-1 table 5 Port Standard Test level Criteria Notes and conditions
EFT
DC power Signal
EN61000-4-4 EN61000-4-4
As per ETS 300 386-1 table 5 As per ETS 300 386-1 table 5
Radiated field Conducted
Enclosure DC power Signal DC power
EN61000-4-3 EN61000-4-6 EN61000-4-6
As per ETS 300 386-1 table 5 As per ETS 300 386-1 table 5 Signal line assumed < 3m in length ETS 300 132, ETR 283
Input transients
File Name: lf_sxe15s.pdf Rev: 09 Sept 2005
4
SXE15 Single Series | 10.8 to 15W DC/DC High Efficiency DC/DC Converters
EMC Electromagnetic Compatibility
Phenomenon Emission: Conducted DC power EN55022 Level A With recommended external filter for compliance bandwidth 20 kHz to 30 MHz, as per ETS 300 386-1. See Application Note 116 for details With recommended external filter for compliance bandwidth 20 kHz to 30 MHz, as per ETS 300 386-1. See Application Note 116 for details Bandwidth 150kHz to 30MHz, as per ETS 300 386-1 Bandwidth 30 MHz to 1 GHz, as per ETS 300 386-1 Port Standard Test level Criteria Notes and conditions
EN55022
Level B
Signal
EN55022
Level B
Radiated
EN55022
Level B
Performance criteria: NP: Normal Performance: EUT shall withstand applied test and operate within relevant limits as specified without damage. RP: Reduced Performance: EUT shall withstand applied test. Reduced performance is permitted within specified limits, resumption to normal performance shall occur at the cessation of the test. LFS: Loss of Function (self recovery): EUT shall withstand applied test without damage, temporary loss of function permitted during test. Unit will self recover to normal performance after test. Referenced ETSI standards: ETS 300 386-1 table 5 (1997): Public telecommunication network equipment, EMC requirements ETS 300 132-2 (1996): Power supply interface at the input to telecommunication equipment: Part 2 operated by direct current (DC) ETR 283 (1997): Transient voltages at interface A on telecommunication direct current (DC) power distributions
Standards Compliance List
Standard EN60950 UL/cUL 1950 TÜV Rheinland Category 2000 3rd edition EN60950:2000
Safety Agency Approvals
Characteristic UL/cUL 1950 File Number TÜV Rheinland Certificate No. E135734 R2074133
Material Ratings
Characteristic - Signal Name Notes and Conditions Flammability rating Material type UL94V-0 FR4 PCB
Model Numbers
Model Number SXE15-48S1V8 SXE15-48S2V5 SXE15-48S3V3 SXE15-48S05 SXE15-48S12 Input Voltage 33-75 33-75 33-75 33-75 33-75 VDC VDC VDC VDC VDC Output Voltage 1.8V 2.5V 3.3V 5V 12V Overvoltage Protection 2.3V 3.2V 4V 6V 15V Output Current (Max) 6A 6A 4.5A 3A 1.25A Typical Efficiency 83% 85% 86% 87% 85% Max. Load Regulation 2.0% 1.5% 0.5% 0.5% 0.5%
5
www.artesyn.com
File Name: lf_sxe15s.pdf Rev: 09 Sept 2005
SXE15 Single Series | SXA10 Series15W15W DC/DC 10.8 to | DC/DC High Efficiency DC/DC Converters
SXE15-48S1V8 Model Input Characteristics
Characteristic Input current - operating Symbol Iin Iin (max.) Min Typ 0.271 Max 0.274 Units A DC Notes and Conditions Vin = Vin (nom); Iout = Iout (max.); Vo = Vo (nom) |