Part Number |
SP-100-xx |
|
Manufacturer |
Total Power International |
|
Semiconductor DataSheet |
|
DataSheet View |
|
www.DataSheet4U.com
TOTAL POWER INT'L
100W Single Output with PFC Function
Features :
Universal AC input / full range
SP-100
series
Built-in active PFC function, PF>0.93 Protections:Short circuit/Over load/Over voltage Built-in constant current limiting circuit Remote ON-OFF control(Optional) LED indicator for power on 100% full load burn-in test Fixed switching frequency at PFC:67KHz PWM:134KHz 3 years warranty
SPECIFICATION
MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT SP-100-3.3 3.3V 20A 0 ~ 20A 66W SP-100-5 5V 20A 0 ~ 20A 100W SP-100-7.5 7.5V 13.5A 0 ~ 13.5A 101.25W 100mVp-p SP-100-12 12V 8.5A 0 ~ 8.5A 102W 100mVp-p SP-100-13.5 SP-100-15 13.5V 7.5A 0 ~ 7.5A 101.25W 100mVp-p 15V 6.7A 0 ~ 6.7A 100.5W 100mVp-p SP-100-24 24V 4.2A 0 ~ 4.2A 100.8W 150mVp-p SP-100-27 27V 3.8A 0 ~ 3.8A 102.6W 150mVp-p SP-100-48 48V 2.1A 0 ~ 2.1A 100.8W 250mVp-p
100mVp-p RIPPLE & NOISE (max.) Note.2 100mVp-p VOLTAGE ADJ. RANGE 3.14 ~ 3.63V 4.75 ~ 5.5V 2.0% VOLTAGE TOLERANCE Note.3 2.0% LINE REGULATION LOAD REGULATION SETUP, RISE, HOLD TIME VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR
0.5%
1.0%
85 ~ 264VAC 47~63Hz PF>0.93/230VAC 70% 76%
7.13 ~ 8.25V 11.4 ~ 13.2V 12.8 ~ 14.9V 14.3 ~ 16.5V 22.8 ~ 26.4V 25.7 ~ 29.7V 45.6 ~ 52.8V 2.0% 2.0% 2.0% 2.0% 1.0% 1.0% 1.0%
0.5%
1.0%
0.5%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
600ms, 30ms, 20ms at full load 120 ~ 370VDC PF>0.98/115VAC at full load 78% 80% 80% 82% 84% 83% 82%
INPUT
EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT (max.) LEAKAGE CURRENT OVER LOAD
1.7A/115VAC 0.8A/230VAC COLD START 40A/230VAC <2mA / 240VAC 105 ~ 150% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 3.63 ~ 4.46V 5.5 ~ 6.75V 8.25 ~ 10.13V 13.2 ~ 16.2V 14.85 ~ 18.23V 16.5 ~ 20.25V 26.4 ~ 32.4V 29.7 ~ 36.45V 52.8 ~ 64.8V
PROTECTION
OVER VOLTAGE FUNCTION
Protection type : Shut down o/p voltage, re-power on to recover REMOTE CONTROL(OPTION) CN1:4 ~ 10VDC POWER ON, <0 ~ 0.8VDC POWER OFF -10 ~ +60 (Refer to output load derating curve) WORKING TEMP.
20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.05%/ (0 ~ 50 VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL1950, TUV EN60950 Approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC SAFETY & ISOLATION RESISTANCE EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B EMC (Note 4) HARMONIC CURRENT Compliance to EN61000-3-2,-3
EMS IMMUNITY MTBF OTHERS DIMENSION PACKING
NOTE
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
211.3K hrs min. MIL-HDBK-217F (25 179*99*45mm (L*W*H) 0.6Kg; 20pcs/12Kg/1.17CUFT )
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
www.DataSheet4U.com
TOTAL POWER INT'L
100W Single Output with PFC Function
Mechanical Specification
179
SP-100
Case No. 915A
series
Unit:mm
20
25
117
123
25
60
65
R.C. +V ADJ.
CN1 1 2 LED 7
6 5 2-M4 L=5mm
51
9.5
4
3 2 1
8
5-M3 L=3mm
49.5
38
15
142
25
16
25
25
3 .5
3-M4 L=6mm
Terminal pin number assignment :
Pin No. 1 2 3 Assignment AC/L AC/N FG Pin No. 4,5 6,7 Assignment DC OUTPUT -V DC OUTPUT +V
Remote ON/OFF(CN1):JST S2B-XH or equivalent(optional)
Pin No. 1 2 Assignment RC+ RCMating Housing JST XHP or equivalent Terminal JST SXH-001T-P0.6 or equivalent
Derating Curve
Output Derating VS Input Voltage
Ta=25
100
SP-100-12~48 SP-100-3.3~7.5 (With 18CFM FAN)
100 90 80
80
60
LOAD (%)
SP-100-3.3 SP-100-5 SP-100-7.5
70
LOAD (%)
40
60 50 40
20
-10 -10
0 0
10 10
20 20
40 45
50 55
55 60
60 (HORIZONTAL) 70 (VERTICAL)
85
100
115
12.5
135
45
10
155
119
79
99
230
264
AMBIENT TEMPERATURE (
)
INPUT VOLTAGE (VAC) 60Hz
|