Si3056 Si 3 0 1 8 / 1 9 /10
GLOBAL SERIAL INTERFACE DIRECT ACCESS ARRANGEMENT
Features
Complete DAA includes the following:
!
Programmable line interface
" AC termination " DC termination " Ring detect threshold " Ringer impedance
! ! ! ! ! ! ! !
80 dB dynamic range TX/RX paths Integrated codec and 2- to 4-wire hybrid Integrated ring detector Type I and II caller ID support Line voltage monitor Loop current monitor Polarity reversal detection Programmable digital gain
! ! ! ! ! ! ! ! ! ! ! !
Clock generation Pulse dialing support Overload detection Low-profile 16-pin SOIC packages 3.3 V power supply Direct interface to DSPs Serial interface control for up to eight devices >5000 V isolation Proprietary isolation technology Parallel handset detection +3.2 dBm TX/RX level mode (600 Ω) Programmable digital hybrid for nearend echo reduction
Ordering Information See page 95.
Pin Assignments
Si3056
Applications
!
V.92 modems ! Set-top boxes ! Voice mail systems ! Fax machines ! Multi-function printers
!
Internet appliances ! Personal digital assistants
MCLK FSYNC SCLK VD SDO SDI FC/RGDT RESET
1 2 3 4 5 6 7 8
16 15 14 13 12 11 10 9
OFHK RGDT/FSD/M1 M0 VA GND AOUT/INT C1A C2A
Description
The Si3056 is an integrated direct access arrangement (DAA) with a programmable line interface to meet global telephone line requirements. Available in two 16-pin small outline packages, it eliminates the need for an analog front end (AFE), an isolation transformer, relays, opto-isolators, and a 2- to 4-wire hybrid. The Si3056 dramatically reduces the number of discrete components and cost required to achieve compliance with global regulatory requirements. The Si3056 interfaces directly to standard modem DSPs.
Si3018/19/10
QE DCT RX IB C1B C2B 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 DCT2 IGND DCT3 QB QE2 SC VREG2 RNG2
Functional Block Diagram
Si3056
MCLK SCLK FSYNC SDI SDO FC/RGDT
Si3018/19/10
RX
VREG RNG1
Digital Interface
Hybrid and dc Termination Isolation Interface Isolation Interface
IB SC DCT VREG VREG2 DCT2 DCT3 RNG1 RNG2 QB QE QE2
US Patent # 5,870,046 US Patent # 6,061,009 Other Patents Pending
RGDT/FSD/M1 OFHK M0 RESET AOUT/INT
Control Interface
Ring Detect Off-Hook
Rev. 1.02 2/04
Copyright © 2004 by Silicon Laboratories
Si3056-DS102
Si3056 Si3018/19/10
2
Rev. 1.02
Si3056 Si3018/19/10 TA B L E O F C O N T E N TS
Section Page
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Typical Application Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Bill of Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 AOUT PWM Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Upgrading from the Si3034/35/44 to Si3056 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Line-Side Device Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 Isolation Barrier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Transmit/Receive Full Scale Level (Si3019 Line-Side Only) . . . . . . . . . . . . . . . . . . . . . . 24 Parallel Handset Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Line Voltage/Loop Current Sensing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Off-Hook . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 DC Termination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 AC Termination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 Transhybrid Balance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 Ring Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Ring Validation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Ringer Impedance and Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Pulse Dialing and Spark Quenching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Billing Tone Detection and Receive Overload . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Billing Tone Filter (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 On-Hook Line Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Caller ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Overload Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Gain Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Filter Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Clock Generation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Digital Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Multiple Device Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Power Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 In-Circuit Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Exception Handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Revision Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Control Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Appendix—UL1950 3rd Edition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 Pin Descriptions: Si3056 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 Pin Descriptions: Si3018/19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Rev. 1.02
3
Si3056 Si3018/19/10
Ordering Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 Evaluation Board Ordering Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 Product Selection and Identification Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 Product Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 Part Designators (Partial List) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .97 SOIC Package Outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 Document Change List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99 Silicon Laboratories® Si3056 Support Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . 101 Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .102
4
Rev. 1.02
Si3056 Si3018/19/10
Electrical Specifications
Table 1. Recommended Operating Conditions
Parameter1 Ambient Temperature Si3056 Supply Voltage, Digital3 Symbol TA VD Test Condition K-Grade Min2 0 3.0 Typ 25 3.3 Max2 70 3.6 Unit °C V
Notes: 1. The Si3056 specifications are guaranteed when the typical application circuit (including component tolerance) and the Si3056 and any Si3018 or Si3019 are used. See Figure 16 on page 17 for typical application schematic. 2. All minimum and maximum specifications are guaranteed and apply across the recommended operating conditions. Typical values apply at nominal supply voltages and an operating temperature of 25 °C unless otherwise stated. 3. 3.3 V applies to both the digital and serial interface and the digital signals RGDT/FSD, OFHK, RESET, M0, and M.
Rev. 1.02
5
Si3056 Si3018/19/10
Table 2. Loop Characteristics
(VD = 3.0 to 3.6 V, TA = 0 to 70 °C for K-Grade, see Figure 1)
Parameter DC Termination Voltage DC Termination Voltage DC Termination Voltage DC Termination Voltage DC Termination Voltage DC Termination Voltage DC Termination Voltage On Hook Leakage Current Operating Loop Current |