http://www.datasheet4u.com

900,000+ Datasheet PDF Search and Download

Datasheet4U offers most rated semiconductors datasheets pdf


Hanwei
Hanwei

MQ7 Datasheet

GAS SENSOR


MQ7 Datasheet Preview


HANWEI ELECTRONICS CO ., LTD
MQ 7
http://www.hwsensor.com
TECHNICAL DATA
MQ-7 GAS SENSOR
FEATURES
* High sensitivity to carbon monoxide
* Stable and long life
APPLICATION
They are used in gas detecting equipment for carbon monoxide(CO) in family and
industry or car.
SPECIFICATIONS
A. Standard work condition
Symbol
Vc
VH (H)
VH (L)
RL
Parameter name
circuit voltage
Heating voltage (high)
Heating voltage (low)
Load resistance
Technical condition
5V±0.1
5V±0.1
1.4V±0.1
Can adjust
Remark
Ac or Dc
Ac or Dc
Ac or Dc
RH
TH (H)
TH (L)
PH
Heating resistance
Heating time (high)
Heating time (low)
Heating consumption
33Ω±5%
60±1 seconds
90±1 seconds
About 350mW
Room temperature
b. Environment conditions
Symbol
Tao
Tas
RH
O2
Parameters
Using temperature
Storage temperature
Relative humidity
Oxygen concentration
c. Sensitivity characteristic
Technical conditions
-20-50
-20-50
Less than 95%RH
21%(stand condition)
the oxygen concentration can
affect the sensitivity
characteristic
Remark
Advice using scope
Minimum value is over 2%
symbol
Rs
а(300/100ppm)
Standard working
condition
Preheat time
Parameters
Technical parameters Remark
Surface resistance
In 100ppm
Of sensitive body
2-20k
Carbon Monoxide
Concentration slope rate
Less than 0.5
Rs (300ppm)/Rs(100ppm)
Temperature -20℃±2relative humidity 65%±5% RL:10KΩ±5%
Vc:5V±0.1V VH:5V±0.1V VH:1.4V±0.1V
No less than 48 hours Detecting range:
20ppm-2000ppm carbon monoxide
www.DataSheet4UD..coSmtructure and configuration, basic measuring circuit
Structure and configuration of MQ-7 gas sensor is shown as Fig. 1 (Configuration A or B),
sensor composed by micro AL2O3 ceramic tube, Tin Dioxide (SnO2) sensitive layer, measuring
electrode and heater are fixed into a crust made by plastic and stainless steel net. The heater
provides necessary work conditions for work of sensitive components. The enveloped MQ-7 have
TEL:86-371-67169070 67169080
FAX:86-371-67169090
Email: sales@hwsensor.com
Page 1

HANWEI ELECTRONICS CO ., LTD
MQ 7
http://www.hwsensor.com
6 pin ,4 of them are used to fetch signals, and other 2 are used for providing heating current.
Parts
1 Gas sensing
layer
2 Electrode
3 Electrode line
4 Heater coil
5 Tubular ceramic
6 Anti-explosion
network
7 Clamp ring
8 Resin base
9 Tube Pin
Materials
SnO2
Au
Pt
Ni-Cr alloy
Al2O3
Stainless steel gauze
(SUS316 100-mesh)
Copper plating Ni
Bakelite
Copper plating Ni
Fig.1
A
A
A
Heating voltage 1.4v (Low) 90s
Heating voltage 5v (High) 60s
VRL
RL
Vc
Fig.2
Standard circuit:
As shown in Fig 2, standard measuring circuit of
MQ-7 sensitive components consists of 2 parts. one
is heating circuit having time control function (the
high voltage and the low voltage work
circularly ). The second is the signal output circuit,
it can accurately respond changes of surface
resistance of the sensor.
Electric parameter measurement circuit is shown as Fig.2
E. Sensitivity characteristic curve
100 MQ-7
10
1
0.1
www.DataSheet4U.com
0.01
10
CO
H2
LPG
CH4
Alcohol
air
100
ppm
1000
10000
Fig.3 sensitivity characteristics of the MQ-7
TEL:86-371-67169070 67169080
FAX:86-371-67169090
Fig.3 is shows the typical
sensitivity characteristics of
the MQ-7 for several gases.
in their: Temp: 20℃、
Humidity: 65%
O2 concentration 21%
RL=10kΩ
Ro: sensor resistance at 100ppm
CO in the clean air.
Rs: sensor resistance at various
concentrations of gases.
Email: sales@hwsensor.com
Page 2

HANWEI ELECTRONICS CO ., LTD
MQ 7
http://www.hwsensor.com
1.5
1.4
1.3
1.2
1.1
1
0.9
0.8
0.7
0.6
0.5
-10 0
MQ-7
10 20
33%RH
85%RH
Fig.4
Temp
30 40 50
Fig.4 is shows the typical
dependence of the MQ-7 on
temperature and humidity.
Ro: sensor resistance at 100ppm CO in
air at 33%RH and 20degree.
Rs: sensor resistance at 100ppm CO at
different temperatures and humidities.
OPERATION PRINCIPLE
. The surface resistance of the sensor Rs is obtained through effected voltage signal output of the
load resistance RL which series-wound. The relationship between them is described:
Rs\RL = (Vc-VRL) / VRL
Fig. 5 shows alterable situation of RL signal output measured by using Fig. 2 circuit output
VH5v
1.4v
In air
60s 90s
In 100ppmCO
In air
Signal
Fig.5
signal when the sensor is shifted from clean air to carbon monoxide (CO) , output signal
measurement is made within one or two complete heating period (2.5 minute from high voltage
to low voltage ).
Sensitive layer of MQ-7 gas sensitive components is made of SnO2 with stability, So, it has
excellent long term stability. Its service life can reach 5 years under using condition.
SENSITVITY ADJUSTMENT
Resistance value of MQ-7 is difference to various kinds and various concentration gases. So, When
using this components, sensitivity adjustment is very necessary. we recommend that you calibrate the
detector for 200ppm CO in air and use value of Load resistance that( RL) about 10 KΩ(5KΩ to 47 KΩ).
When accurately measuring, the proper alarm point for the gas detector should be determined after
considering the temperature and humidity influence. The sensitivity adjusting program:
a. Connect the sensor to the application circuit.
b. Turn on the power, keep preheating through electricity over 48 hours.
www.DataSheet4U.cco.mAdjust the load resistance RL until you get a signal value which is respond to a certain
carbon monoxide concentration at the end point of 90 seconds.
d. Adjust the another load resistance RL until you get a signal value which is respond to a CO
concentration at the end point of 60 seconds .
Supplying special IC solutions, More detailed technical information, please contact us.
TEL:86-371-67169070 67169080
FAX:86-371-67169090
Email: sales@hwsensor.com
Page 3
Part Number MQ7
Manufactur Hanwei
Description GAS SENSOR
Total Page 3 Pages
PDF Download
MQ7 datasheet
Download PDF File
MQ7 datasheet
View Html for PC & Mobile


Related Datasheet

MQ-1168 , MQ-1168 , MQ-131 , MQ-135 , MQ-2 , MQ-306 , MQ-6 , MQ-6 , MQ-7 , MQ-Wxxx , MQ1 , MQ1.5 , MQ10 , MQ100 , MQ12 , MQ125 , MQ13 , MQ131 , MQ131 , MQ131 , MQ135 , MQ150 , MQ2 , MQ2218 , MQ2218 , MQ2218A , MQ2219 , MQ2219 , MQ2219A , MQ307A , MQ307A , MQ3251 , MQ3251 , MQ4 , MQ6 , MQ6 , MQ6001 , MQ7 , MQ80960MC , MQ80960XA , MQ82C55A , MQ82C55A , MQC02006 , MQC020xx , MQC202-xxx , MQC202-xxx , MQC308-xxx , MQC308-xxx , MQC309-xxx , MQC309-xxx , MQC505-xxx , MQC505-xxx , MQC506-xxx , MQC508-xxx , MQC513-xxx , MQC513-xxx , MQC515-xxx , MQC530-xxx , MQC530-xxx , MQO ,

site map

webmaste! click here

contact us

Buy Components