Part Number |
MCP1317 |
|
Manufacturer |
Microchip Technology |
|
Semiconductor DataSheet |
|
DataSheet View |
|
www.DataSheet4U.com
MCP131X/2X
Voltage Supervisor
Features
• Low supply current: 1 μA (typ.), 10 μA (max.) • Precision monitoring trip point options: - 2.9V and 4.6V (Standard Offerings) - 2.0V to 4.7V in 100 mV increments, (Contact the local Microchip Sales Office) • Resets microcontroller in a power-loss event • Reset Delay Time Out Option: - 1.4 ms, 30 ms, 200 ms, or 1.6s (typ.) • Watchdog Timer Input Time Out Options: - 6.3 ms, 102 ms, 1.6s or 25.6s (typ.) • Manual Reset (MR) input (active-low) • Single and complementary Reset output(s) • Reset Output Options: - Push-Pull (active-high or active-low) - Open-Drain (internal or external Pull-up) • Temperature Range: -40°C to +125°C • Voltage Range: 1.0V to 5.5V • Lead Free Packaging
Package Types
SOT-23-5
MCP1316/16M/20 MCP1317
RST VSS MR
1 2 3
5
VDD WDI
RST VSS
1 2 3
5
VDD WDI
4
MR
4
MCP1318/18M/21
MCP1319/19M/22
RST VSS RST
1 2 3
5
VDD
RST VSS
1 2 3
5
VDD
4
WDI
RST
4
MR
Block Diagram
VDD + – Comparator RST Reference Voltage Noise Filter Watchdog VSS Output Driver RST
Description
The MCP1316/16M/17/18/18M/19/19M/20/21/22 are voltage supervisor devices designed to keep a microcontroller in Reset until the system voltage has reached and stabilized at the proper level for reliable system operation. This sevice family also offers a Watchdog Timer to monitor system operation and a Manual Reset input. The table below shows the available features for these devices. MR WDI
Note: Features available depend on the device
Device Features
Reset Output A Device MCP1316 MCP1316M MCP1317 MCP1318 MCP1318M MCP1319 MCP1319M MCP1320 MCP1321 MCP1322 Type Push-Pull Open-Drain Push-Pull Push-Pull Open-Drain Push-Pull Open-Drain Open-Drain Open-Drain Open-Drain Pull-up Resistor — Internal — — Internal — Internal External External External Active Level Low Low High Low Low Low Low Low Low Low Reset Output B Type — — — Push-Pull Push-Pull Push-Pull Push-Pull — Push-Pull Push-Pull Pull-up Resistor — — — — — — — — — — Active Level — — — High High High High — High High WDI Input Yes Yes Yes Yes Yes No No Yes Yes No MR Input Yes Yes Yes No No Yes Yes Yes No Yes
© 2005 Microchip Technology Inc.
DS21985A-page 1
www.DataSheet4U.com
MCP131X/2X
1.0 ELECTRICAL CHARACTERISTICS
† Notice: Stresses above those listed under “Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and functional operation of the device at those or any other conditions above those indicated in the operational listings of this specification is not implied. Exposure to maximum rating conditions for extended periods may affect device reliability.
Absolute Maximum Ratings†
Supply Voltage (VDD to VSS) . . . . . . . . . . . . . . . . . . . . . . 7.0V Input current (VDD) . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 mA Output current (RST) . . . . . . . . . . . . . . . . . . . . . . . . . .10 mA Voltage on all inputs and outputs, except Open-Drain RST (with no internal pull-up resistor), w.r.t. VSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.6V to (VDD + 1.0V) Voltage on Open-Drain RST (with no internal pull-up resistor) w.r.t. VSS . . -0.6V to 13.5V Storage temperature . . . . . . . . . . . . . . . . . . .-65°C to +150°C Ambient temp. with power applied . . . . . . . .-40°C to +125°C Maximum Junction temp. with power applied . . . . . . . . 150°C Power Dissipation (TA ≤ 70°C): 5-Pin SOT-23A .......................................................240 mW ESD protection on all pins ..................................................≥ 4 kV
DC CHARACTERISTICS
Electrical Specifications: Unless otherwise indicated, all limits are specified for VDD = 1V to 5.5V, RPU = 100 kΩ (only MCP1320, MCP1321 and MCP1322), TA = -40°C to +125°C. Parameters Operating Voltage Range Specified VDD Value to VOUT Low Operating Current: Sym VDD VDD IDD Min 1.0 1.0 — — — — Note 1: 2: 3: 4: Typ — — 5 1 1 5 Max 5.5 — 10 2 2 10 Units V V μA μA μA μA I RST = 10 μA, V RST < 0.3V Watchdog Timer Active Watchdog Timer Inactive VDD < VTRIP Reset Delay Timer Active Conditions
5: 6:
Trip point is ±1.5% from typical value. Trip point is ±2.5% from typical value. Hysterysis is minimum = 1%, max = 6% at +25°C. This specification allows this device to be used in PICmicro® microcontroller applications that require the In-Circuit Serial Programming™ (ICSP™) feature (see device-specific programming specifications for voltage requirements). The total time that the RST pin can be above the maximum device operational voltage (5.5V) is 100s. Current into the RST pin should be limited to 2 mA. It is recommended that the device operational temperature be maintained between 0°C to +70°C (+25°C preferred). For additional information, refer to Figure 2-35. This parameter is established by characterization and is not 100% tested. Custom ordered voltage trip point; minimum order volume requirement. Information available upon request.
DS21985A-page 2
© 2005 Microchip Technology Inc.
www.DataSheet4U.com
MCP131X/2X
DC CHARACTERISTICS (CONTINUED)
Electrical Specifications: Unless otherwise indicated, all limits are specified for VDD = 1V to 5.5V, RPU = 100 kΩ (only MCP1320, MCP1321 and MCP1322), TA = -40°C to +125°C. Parameters VDD Trip Point MCP13XX-20 (Note 6) MCP13XX-21 (Note 6) MCP13XX-22 (Note 6) MCP13XX-23 (Note 6) MCP13XX-24 (Note 6) MCP13XX-25 (Note 6) MCP13XX-26 (Note 6) MCP13XX-27 (Note 6) MCP13XX-28 (Note 6) MCP13XX-29 MCP13XX-30 (Note 6) MCP13XX-31 (Note 6) MCP13XX-32 (Note 6) MCP13XX-33 (Note 6) Note 1: 2: 3: 4: Sym VTRIP Min 1.970 1.950 2.069 2.048 2.167 2.145 2.266 2.243 2.364 2.340 2.463 2.438 2.561 2.535 2.660 2.633 2.758 2.730 2.857 2.828 2.955 2.925 3.054 3.023 3.152 3.120 3.251 3.218 Typ 2.00 2.00 2.10 2.10 2.20 2.20 2.30 2.30 2.40 2.40 2.50 2.50 2.60 2.60 2.70 2.70 2.80 2.80 2.90 2.90 3.00 3.00 3.10 3.10 3.20 3.20 3.30 3.30 Max 2.030 2.050 2.132 2.153 2.233 2.255 2.335 2.358 2.436 2.460 2.538 2.563 2.639 2.665 2.741 2.768 2.842 2.870 2.944 2.973 3.045 3.075 3.147 3.178 3.248 3.280 3.350 3.383 Units V V V V V V V V V V V V V V V V V V V V V V V V V V V V Conditions TA = +25°C (Note 1) TA = -40°C to +85°C (Note 2) TA = +25°C (Note 1) TA = -40°C to +85°C (Note 2) TA = +25°C (Note 1) TA = -40°C to +85°C (Note 2) TA = +25°C (Note 1) TA = -40°C to +85°C (Note 2) TA = +25°C (Note 1) TA = -40°C to +85°C (Note 2) TA = +25°C (Note 1) TA = -40°C to +125°C (Note 2) TA = +25°C (Note 1) TA = -40°C to +125°C (Note 2) TA = +25°C (Note 1) TA = -40°C to +125°C (Note 2) TA = +25°C (Note 1) TA = -40°C to +125°C (Note 2) TA = +25°C (Note 1) TA = -40°C to +125°C (Note 2) TA = +25°C (Note 1) TA = -40°C to +125°C (Note 2) TA = +25°C (Note 1) TA = -40°C to +125°C (Note 2) TA = +25°C (Note 1) TA = -40°C to +125°C (Note 2) TA = +25°C (Note 1) TA = -40°C to +125°C (Note 2)
5: 6:
Trip point is ±1.5% from typical value. Trip point is ±2.5% from typical value. Hysterysis is minimum = 1%, max = 6% at +25°C. This specification allows this device to be used in PICmicro® microcontroller applications that require the In-Circuit Serial Programming™ (ICSP™) feature (see device-specific programming specifications for voltage requirements). The total time that the RST pin can be above the maximum device operational voltage (5.5V) is 100s. Current into the RST pin should be limited to 2 mA. It is recommended that the device operational temperature be maintained between 0°C to +70°C (+25°C preferred). For additional information, refer to Figure 2-35. This parameter is established by characterization and is not 100% tested. Custom ordered voltage trip point; minimum order volume requirement. Information available upon request.
© 2005 Microchip Technology Inc.
DS21985A-page 3
www.DataSheet4U.com
MCP131X/2X
DC CHARACTERISTICS (CONTINUED)
Electrical Specifications: Unless otherwise indicated, all limits are specified for VDD = 1V to 5.5V, RPU = 100 kΩ (only MCP1320, MCP1321 and MCP1322), TA = -40°C to +125°C. Parameters VDD Trip Point (Con’t) MCP13XX-34 (Note 6) MCP13XX-35 (Note 6) MCP13XX-36 (Note 6) MCP13XX-37 (Note 6) MCP13XX-38 (Note 6) MCP13XX-39 (Note 6) MCP13XX-40 (Note 6) MCP13XX-41 (Note 6) MCP13XX-42 (Note 6) MCP13XX-43 (Note 6) MCP13XX-44 (Note 6) MCP13XX-45 (Note 6) MCP13XX-46 MCP13XX-47 (Note 6) VDD Trip Point Tempco Note 1: 2: 3: 4:
TTPCO
Sym VTRIP
Min 3.349 3.315 3.448 3.413 3.546 3.510 3.645 3.608 3.743 3.705 3.842 3.803 3.940 3.900 4.039 3.998 4.137 4.095 4.236 4.193 4.334 4.290 4.433 4.388 4.531 4.485 4.630 4.583
—
Typ 3.40 3.40 3.50 3.50 3.60 3.60 3.70 3.70 3.80 3.80 3.90 3.90 4.00 4.00 4.10 4.10 4.20 4.20 4.30 4.30 4.40 4.40 4.50 4.50 4.60 4.60 4.70 4.70
±40
Max 3.451 3.385 3.553 3.588 3.654 3.690 3.756 3.793 3.857 3.895 3.959 3.998 4.060 4.100 4.162 4.203 4.263 4.305 4.365 4.408 4.466 4.510 4.568 4.613 4.669 4.715 4.771 4.818
—
Units V V V V V V V V V V V V V V V V V V V V V V V V V V V V
ppm/°C
Conditions TA = +25°C (Note 1) TA = -40°C to +125°C (Note 2) TA = +25°C (Note 1) TA = -40°C to +125°C (Note 2) TA = +25°C (Note 1) TA = -40°C to +125°C (Note 2) TA = +25°C (Note 1) TA = -40°C to +125°C (Note 2) TA = +25°C (Note 1) TA = -40°C to +125°C (Note 2) TA = +25°C (Note 1) TA = -40°C to +125°C (Note 2) TA = +25°C (Note 1) TA = -40°C to +125°C (Note 2) TA = +25°C (Note 1) TA = -40°C to +125°C (Note 2) TA = +25°C (Note 1) TA = -40°C to +125°C (Note 2) TA = +25°C (Note 1) TA = -40°C to +125°C (Note 2) TA = +25°C (Note 1) TA = -40°C to +125°C (Note 2) TA = +25°C (Note 1) TA = -40°C to +125°C (Note 2) TA = +25°C (Note 1) TA = -40°C to +125°C (Note 2) TA = +25°C (Note 1) TA = -40°C to +125°C (Note 2)
5: 6:
Trip point is ±1.5% from typical value. Trip point is ±2.5% from typical value. Hysterysis is minimum = 1%, max = 6% at +25°C. This speci |