Part Number |
LCP-200A4HSR |
|
Manufacturer |
Delta Electronics |
|
Semiconductor DataSheet |
|
DataSheet View |
|
RoHS Compliant Small Form Factor Pluggable Transceiver RoHS Compliant for ESCON, Fast Ethernet, ATM, SONET OC-3/SDH STM-1
FEATURES
Compliant with SFP Transceiver MSA specification Compliant with Industry Standard RFT Electrical Connector and Cage 1310nm LED Source Technology Single + 3.3V Power Supply and TTL Logic Interface EEPROM with Serial ID Functionality Laser Class 1 Product which comply with the requirements of IEC 60825-1 and IEC 60825-2 Duplex LC Connector interface
Description
Applications
www.DataSheet4U.com The LCP-200A4HSR is a hot pluggable 3.3V ESCON Small-Form-Factor transceiver module designed expressly for high-speed communication SONET OC-3/SDH STM-1 applications that require rates of up to 200Mbit/sec. It is compliant with the SFP ATM Network Multi-source Agreement. Fast Ethernet The LCP-200A4HSR transceivers provide with Switch to Switch interface the LC receptacle that is compatible with the industry standard LC connector. The transceiver Switched backplane applications is also compatible with industry standard RFT connector and cage. File server interface
The transmitter section consists of a 1310nm LED in an optical subassembly (OSA) while the receiver consists of InGaAs PIN photodiode mounted together with a trans-impedance preamplifier. The post-amplifier also includes a LOS (Loss Of Signal) circuit that provides a TTL logic-high output when an unusable optical signal level is detected. The LCP-200A4HSR transceiver is a Class 1 eye safety product. The optical power levels, under normal operation, are at eye safe level.
Data Link up to 2km in 62.5/125um Multi Mode Fiber
1
DELTA ELECTRONICS, INC.
Aug., 2006 Rev. 0A
www.deltaww.com
Absolute Maximum Ratings
Parameter Storage Temperature Supply Voltage Symbol Ts VCC Min. -40 0 Typ. Max. 85 5 Unit ºC V Note
Recommended Operating Conditions
Parameter Case Operating Temperature Supply Voltage
Note 1: See order information
Symbol TC VCC
Min. -5 3.135
Typ.
Max. 70 3.465
Unit ºC V
Note 1
Electrical Characteristics
(VCC=3.135V to 3.465V) Parameter Total Supply Current Transmitter Transmitter Differential Input Voltage Transmitter Disable Input-High Transmitter Disable Input-Low Transmitter Fault Output-High Transmitter Fault Output-Low Receiver Receiver Differential Output Voltage LOS Output Voltage-High LOS Output Voltage-Low Output Data rise time/ fall time Symbol ICCT VDT VDISH VDISL VTXFH VTXFL VDR VLOSH VLOSL tr/tf Min. 0.5 2 0 2 0 0.35 2 0 Typ. Max. 300 2.4 VCC+0.3 0.8 VCC+0.3 0.8 2 VCC+0.3 0.8 1.5 Unit mA V V V V V V V V ns Note 1 2 2 3 1 1 4
Notes 1. Internally AC coupled and terminated to 100 Ohm differential load. 2. Pull up to VCC with a 4.7K – 10KΩ resistor on host Board 3. Internally AC coupled, but requires a 100 Ohm differential termination at or internal to Serializer/ Deserializer. 4. These are 20%~80% values.
2
DELTA ELECTRONICS, INC.
Aug., 2006 Rev. 0A
www.deltaww.com
Optical Characteristics
(VCC=3.135V to 3.465V, Data Rate=200Mb/sec, PRBS=223-1 NRZ, 62.5/125um MMF) Parameter Transmitter Output Optical Power (Avg.) Optical Extinction Ratio Center Wavelength Spectral Width (RMS) Optical rise time/ fall time Relative Intensity Noise Receiver Sensitivity (Avg.) Input Optical Wavelength LOS-Deasserted (Avg.) LOS-Asserted (Avg.) LOS-Hysteresis Overload Symbol PO
C
Min. -20 9
Typ.
Max. -14
Unit dBm dB nm nm ns dB/Hz dBm nm dBm dBm dB dBm
Note
1310 200 3 -117 -31 1600 -31
tr/tf RIN PIN 1100 PA PD PA-PD PO -48 0.5 -14 1310
1
2
Notes: 1. These are unfiltered 10%~90% values 2. The sensitivity is provided at a BER of 1×10-10 or better with an input signal consisting of 200Mb/s, 223-1 PRBS and ER=9dB.
3
DELTA ELECTRONICS, INC.
Aug., 2006 Rev. 0A
www.deltaww.com
SFP Transceiver Electrical Pad Layout
Pin Function Definitions
Pin Num. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Name VeeT TX Fault TX Disable MOD-DEF2 MOD-DEF1 MOD-DEF0 Rate Select LOS VeeR VeeR VeeR RDRD+ VeeR VccR VccT VeeT TD+ TDVeeT Function Transmitter Ground Transmitter Fault Indication Transmitter Disable Module Definition 2 Module Definition 1 Module Definition 0 Not Connect Loss of Signal Receiver Ground Receiver Ground Receiver Ground Inv. Received Data Out Received Data Out Receiver Ground Receiver Power Transmitter Power Transmitter Ground Transmit Data In Inv. Transmit Data In Transmitter Ground Plug Seq. Notes 1 3 Note 1 Note 2 3 Module disables on high or open 3 Note 3, 2 wire serial ID interface 3 Note 3, 2 wire serial ID interface 3 Note 3, Grounded in Module 3 Function not available 3 Note 4 1 Note 5 1 Note 5 1 Note 5 3 Note 6 3 Note 7 1 Note 5 2 3.3 ± 10%, Note 7 2 3.3 ± 10%, Note 7 1 Note 5 3 Note 8 3 Note 8 1 Note 5
Plug Seq.: Pin engagement sequence during hot plugging.
4
DELTA ELECTRONICS, INC.
Aug., 2006 Rev. 0A
www.deltaww.com
Notes: 1) TX Fault is an open collector/drain output, which should be pulled up with a 4.7K – 10KΩ resistor on the host board. Pull up voltage between 2.0V and VccT, R+0.3V. When high, output indicates a laser fault of some kind. Low indicates normal operation. In the low state, the output will be pulled to < 0.8V. 2) TX disable is an input that is used to shut down the transmitter optical output. It is pulled up within the module with a 4.7 – 10 K Ω resistor. Its states are: Low (0 – 0.8V): (>0.8, < 2.0V): High (2.0 – 3.465V): Open: 3) Transmitter on Undefined Transmitter Disabled Transmitter Disabled
Mod-Def 0,1,2. These are the module definition pins. They should be pulled up with a 4.7K – 10KΩresistor on the host board. The pull-up voltage shall be VccT or VccR (see Section IV for further details). Mod-Def 0 is grounded by the module to indicate that the module is present Mod-Def 1 is the clock line of two wire serial interface for serial ID Mod-Def 2 is the data line of two wire serial interface for serial ID
4)
LOS (Loss of Signal) is an open collector/drain output, which should be pulled up with a 4.7K – 10KΩ resistor. Pull up voltage between 2.0V and VccT, R+0.3V. When high, this output indicates the received optical power is below the worst-case receiver sensitivity (as defined by the standard in use). Low indicates normal operation. In the low state, the output will be pulled to < 0.8V.
5) 6)
VeeR and VeeT may be internally connected within the SFP module. RD-/+: These are the differential receiver outputs. They are AC coupled 100Ω differential lines which should be terminated with 100Ω (differential) at the user SERDES. The AC coupling is done inside the module and is thus not required on the host board. The voltage swing on these lines will be between 370 and 2000 mV differential (185 – 1000 mV single ended) when properly terminated.
7)
VccR and VccT are the receiver and transmitter power supplies. They are defined as 3.3V ±10% at the SFP connector pin. Maximum supply current is 300 mA. Recommended host board power supply filtering is shown below. Inductors with DC resistance of less than 1 ohm should be used in order to maintain the required voltage at the SFP input pin with 3.3V supply voltage. When the recommended supply-filtering network is used, hot plugging of the SFP transceiver module will result in an inrush current of no more than 30 mA greater than the steady state value. VccR and VccT may be internally connected within the SFP transceiver module.
8) TD-/+: These are the differential transmitter inputs. They are AC-coupled, differential lines with 100 Ω differential termination inside the module. The AC coupling is done inside the module and is thus not required on the host board. The inputs will accept differential swings of 500 – 2400 mV (250 – 1200 mV single-ended), though it is recommended that values between 500 and 1200 mV differential (250 – 600 mV single-ended) be used for best EMI performance.
5
DELTA ELECTRONICS, INC.
Aug., 2006 Rev. 0A
www.deltaww.com
Recommend Circuit Schematic
VCC 3.3V 1uH 1uH 10uF 0.1uF 0.1uF
Protocol Vcc
DELTA SFP Module
VccT
10k Ohms
Tx_Disable
Tx_Disable Tx_Fault TD +
0.01uF 100 Ohms
Laser Driver
Laser Diode
TD -
0.01uF
Protocol IC
SerDes IC
RES1 10uF
VeeT VccR
0.1uF
RD +
100 Ohms*
0.01uF
Preamp & Quantizer
Photo Diode
RD Rx_LOS
3.3V
0.01uF
Rx_LOS VeeR
RES1
RES1
RES1
PLD / PAL
Mod_def 2 Mod_def 1 Mod_def 0
EEPROM
RES1 = 4.7k to 10k Ohms * Depands on SerDes IC used
6
DELTA ELECTRONICS, INC.
Aug., 2006 Rev. 0A
www.deltaww.com
Package Outline Drawing for Metal Housing with Bail de-latch
7
DELTA ELECTRONICS, INC.
Aug., 2006 Rev. 0A
www.deltaww.com
SFP timing parameters for SFP management
Parameter Symbol Min. Max.
TX_DISABLE Assert time TX_DISABLE Negate time
t_off t_on
10 1 300 100 10 100 100 100
Unit Conditions Time from rising edge of TX_DISABLE to µsec when the optical output falls below 10% of nominal Time from falling edge of TX_DISABLE to msec when the modulated optical output rises above 90% of nominal
Unit
Time to initialize, including reset of t_init TX_FAULT TX Fault Assert t_fault Time TX_DISABLE to t_rest reset LOS Assert Time t_loss_on LOS Deassert Time t_loss_off Serial ID Clock Rate f_serial_clock
msec
From power on or negation of TX_Fault using TX Disable.
µsec Time from fault to TX fault on.
Time TX Disbale must be held high to reset TX_Fault µsec Time from LOS state to Rx LOS assert µsec Time from non-LOS state to Rx LOS deassert kHz
µsec
LCP-200A4HSR EEPROM Serial ID Memory Contents (2-Wire Address A0h)
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Hex ASCII 03 04 07 00 80 00 00 00 00 00 00 00 02 00 00 00 00 C8 00 00 44 D 45 E 4C L 54 T 41 A 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 Hex ASCII 20 20 20 20 20 20 20 20 20 20 20 00 00 00 00 4C L 43 C 50 P 2D 32 2 30 0 30 0 41 A 34 4 48 H 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 Hex ASCII 53 S 52 R 20 20 20 20 30 30 30 30 05 1E 00 CS1 Note 1 00 1A 05 05 SN Note 2 SN SN |