Part Number |
HA10 |
|
Manufacturer |
LEM |
|
Semiconductor DataSheet |
|
DataSheet View |
|
www.DataSheet4U.com
Current Transducer HA 10 to 25-NP
For the electronic measurement of DC, AC and pulsed currents, with a galvanic isolation between the primary (high power) circuit and the secondary (electronic) circuit.
IPN = 5 .. 25 A
Electrical data
Primary Nominal Rms current IPN (A) Primary terminal connections HA 10-NP HA 25-NP ÎP VOUT RL VC IC Vb Vd Series ±5 ± 12.5 Parallel ± 10 ± 25 Primary Current measuring range IP (A) Series 0 .. ± 10 0 .. ± 25 50 x IPN ±4 >4 ± 15 < 20 500 2.5 1 > 500 Parallel 0 .. ± 20 0 .. ± 50 A V kΩ V mA V kV kV MΩ
Features
• Open loop transducer using Hall
Effect
Ris
Overload capacity (1 ms) Analogue output voltage @ ± IPN Load resistance Supply voltage (± 5 %) Current consumption (max) Rms rated voltage1) Rms voltage for AC isolation test, 50 Hz, 1 mn Primary to secondary Primary 1 to primary 2 2) Isolation resistance @ 500 VDC
• Printed circuit board mounting • Insulated plastic case to UL 94-V0 • Externally programmable for
desired rating
• Galvanic isolation between primary
windings.
Advantages
• • • • • • • • • •
Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, 5 to 50 A in one package Easy to mount with automated handling systems.
Accuracy - Dynamic performance data
ε
X
L
Accuracy 3) @ IPN, TA = 25°C, @ ± 15 V Linearity 3) Electrical offset voltage @ IP = 0, TA = 25°C Residual offset voltage @ IP = 0 after an overload of 3 x IPN Thermal drift of offset voltage TA = - 10 .. + 80°C Thermal drift of gain TA = - 10 .. + 80°C Response time @ 90 % of IP di/dt accurately followed Frequency bandwidth (- 3 dB) 4)
VOE VOM VOT TCεG ε tr di/dt f
±1 ±1 Max ± 30 ± 20 ±3 ± 0.07 <3 > 50 DC .. 50
% % mV mV mV/°K %/°K µs A/µs kHz
Applications
• AC variable speed drives and servo
motor drives
General data
TA TS m Ambient operating temperature Ambient storage temperature Mass Standards 5) - 10 .. + 80 °C - 25 .. + 85 °C 10 g EN50178 (1994)
• Static converters for DC motor drives • Battery supplied applications • Uninterruptable Power Supplies
(UPS)
• Switched Mode Power Supplies
Notes :
1) 2) 3) 4)
5)
Overvoltage Category III, Pollution Degree 2 Primary 1 is between A and B, primary 2 is between C and D Excludes the electrical offset Refer to derating curves in the technical file to avoid excessive core heating at high frequency Please consult characterisation report for more technical details and application advice.
(SMPS)
• Power supplies for welding
applications.
HANP980903/1
LEM Components
www.lem.com
www.DataSheet4U.com
Dimensions HA 10 to 25-NP (in mm. 1 mm = 0.0394 inch)
Bottom view Left view
Primary connections
Series A: IP in D: IP out Connect B to C IP in IP out
Parallel A + C : B+D : Isolated primary A: B: C: D:
Primary 1 IP in Primary 1 IP out Primary 2 IP in Primary 2 IP out
Front view
Secondary terminals
Terminal Terminal Terminal Terminal 1 2 3 4 : supply voltage - 15 V : 0V : supply voltage + 15 V : output
Mechanical characteristics
• General tolerance ± 0.5 mm • Fastening & connection of primary
HA 10-NP 4 pins Ø 0.71 mm HA 25-NP 4 pins Ø 1.4 mm Recommended pcb hole HA 10-NP 4 pins Ø 1 mm HA 25-NP 4 pins Ø 1.8 mm • Fastening & connection of secondary 4 pins Ø 0.51 x 0.25 mm Recommended pcb hole Ø 1 mm
Remarks
• VOUT is positive when IP flows in the direction of the arrow. • This is a standard model. For different versions (supply
voltages, secondary connections, unidirectional measurements, operating temperatures, etc.) please contact us.
LEM have a policy of continual product improvement and the company reserves the right to revise the above specification without prior notice.
|