GV2P32 Datasheet

Manual Starter and Protector


GV2P32 Datasheet Preview


www.schneider-electric.us
GV2ME
GV2P21 with
GV2GH7 installed
Starters
TeSys® GV2 and GV3 Manual Starter and Protector
Refewr wtowC.DaatatalSohgee2t542U0.cComT0001
The GV family of products are 3-pole, horsepower rated, UL 508 listed, manual starters. They include a manual
disconnect, class 10 ambient-compensated thermal overload relay, and an instantaneous magnetic trip mechanism in
one compact unit.
Any GV manual starter can be used alone for local manual control of a motor with individual full-load currents up to 220
amps. The GV family of products may also be used in group motor installations in accordance with National Electric
Code article 430-53. Group motor installations give you greater panel density for smaller size and require fewer parts
and less wiring necessary for installation when compared to conventional panel designs.
The GV2P and GV3P products also have an additional UL 508 type E rating as a stand alone self-protected manual
combination starter. The UL 508 type E rating requires the addition of line side insulating barrier GV2GH7 for the GV2P
or part number GV3G66 for the GV3P. The GV2P and the GV3P self-protected manual combination starter may also
be combined with specific size contactors from the LC1D product family for a UL 508 Type F combination starter
construction. These products have UL-listed short circuit current rating from 10–100 KA depending on application size
and voltage. See www.us.telemecanique.com for more information.
How to Order
To order the basic motor starter, select the model number (GV2ME••, GV2P••, or GV3P••) with the appropriate thermal
setting from the table below. The thermal trip range and setting should be determined from the motor nameplate full-
load current.
Table 18.124:
Thermal
Setting
(A)
Maximum Horsepower Ratings
1Ø 3Ø
115 V 230 V 200 V 230 V 460 V
hp hp hp hp hp
575 V
hp
Group Motor
Applications
Max. Fuse or
Circuit Breaker
GV2/3M push button
Catalog
Number
$ Price
GV2/3P rotary handle
Catalog
Number
$ Price
0.11–0.16 — — — — — —
1200 A
GV2ME01a
159.
GV2P01
212.
0.16–0.25 — — — — — —
1200 A
GV2ME02a
159.
GV2P02
212.
0.25–0.40 — — — — — —
1200 A
GV2ME03a
159.
GV2P03
212.
0.40–0.63 — — — — — —
1200 A
GV2ME04a
180.
GV2P04
233.
0.63–1 — — — — 0.5 0.5
1200 A
GV2ME05a
180.
GV2P05
233.
1–1.6
— 0.1 —
— 0.75
1
1200 A
GV2ME06a
180.
GV2P06
233.
1.6–2.5
— 0.667 0.5
0.5
1
1.5
2.5–4
1/8 0.333 0.75
1
2
3
1200 A
1200 A
GV2ME07a
GV2ME08a
180.
180.
GV2P07
GV2P08
233.
233.
4–6.3
1/4 0.5 1.5 1.5
3
5
1200 A
GV2ME10a
180.
GV2P10
233.
6–10
0.5 1.5
2
3
5 7.5
1200 A
GV2ME14a
180.
GV2P14
233.
9–14 0.75 2 3 3 10 10
1200 A
GV2ME16a
224.
GV2P16
278.
13–18 1 3 5 5 10 15
1200 A
GV2ME20a
224.
GV2P20
278.
17–23 1.5 3
5 7.5 15 20
1200 A
GV2ME21a
224.
GV2P21
278.
20–25 2 3 5 7.5 15 20
1200 A
GV2ME22a
224.
GV2P22
278.
24–32 2 5 10 10 20 30
1200 A
GV2ME32
224.
GV2P32
278.
9–13
12–18
0.5 1.5
0.75 2
3
5
3 7.5 10
5 7.5 10
——
GV3P13
404.
New! GV3P18
404.
17–25 1.5 3 7.5 7.5 15 20
——
GV3P25
404.
23–32 2 3 10 7.5 20 25
——
GV3P32
404.
30–40 3 5 10 10 25 30
——
GV3P40
504.
37–50
3 7.5 15 10 30 40
——
GV3P50
504.
48–65 3 10 20 15 40 50
——
GV3P65
504.
a For spring terminals add 3 to the catalog number, for example, GV2ME013. GV2ME32 is not available with spring terminals.
GV3P
GV7RE20
Table 18.125:
Thermal
Setting
(A)
Maximum Horsepower Ratings
1Ø 3Ø
115 V 230 V 200 V 230 V 460 V
hp hp hp hp hp
575 V
hp
12–20
15–25
25–40
30–50
48–80
60–100
90–150
132–220
— — — 5 10 15
— — — 7.5 15 20
— — — 10 30 30
— — — 15 30 40
— — — 30 60 75
— — — 30 75 100
— — — 50 100 150
— — — 75 150 200
Toggle Operator
Standard Interrupt
High Interrupt
Catalog
Number
GV7RE20
GV7RE25
GV7RE40
GV7RE50
GV7RE80
GV7RE100
GV7RE150
GV7RE220
$ Price
417.
417.
417.
417.
417.
456.
502.
502.
Catalog
Number
GV7RS20
GV7RS25
GV7RS40
GV7RS50
GV7RS80
GV7RS100
GV7RS150
GV7RS220
$ Price
813.
813.
813.
813.
813.
891.
978.
978.
Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-36
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-34 to 18-35
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-52 to 18-55
E164864
CCN NLRV
LR81630
Class 3211 05
© 2009 Schneider Electric
All Rights Reserved
I11
Discount
Schedule
18-33
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Page 1

Starters Accessories
TeSys® GV2 and GV3 Manual Starters and Protectors
Refer to Catalog 2502CT0001 wwww.wDwa.tsacShhneeeidt4eUr-e.cleocmtric.us
GVAU116
Table 18.126: Voltage Trips
Only one trip or fault signaling contact can be installed per GV2/GV3 device.
Description
Characteristics
Voltage
Frequency
Catalog Numbera
$ Price
24 V
50 Hz
60 Hz
GVA025
GVA026
48 V
100–110 V
50 Hz
60 Hz
50/60 Hz
GVA055
GVA056
GVA107
110–115 V
120–127 V
50 Hz
60 Hz
50 Hz
GVA115
GVA116
GVA125
127 V
60 Hz
GVA115
Voltage trips
GV2 & GV3P
Undervoltage or
Shunt trip
(external mount,
1 block right side only)
200 V
200–220 V
220–240 V
380–400 V
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
GVA207
GVA207
GVA225
GVA226
GVA385
GVA386
81.00
415–440 V
415 V
50 Hz
60 Hz
GVA415
GVA416
440 V
60 Hz
GVA385
480 V
60 Hz
GVA415
500 V
600 V
50 Hz
60 Hz
GVA505
a To order an under voltage trip: replace the bullet () with a U, example: GVAU025. To order a shunt trip: replace the bullet () with an S, example:
GVAS025.
Table 18.127: Auxiliary Contact Blocks
GVAE11
Description
Mounting
Location
Max. No. of
Blocks
Contact Type
Sold in lots of
N.O. or N.C.c
1
Instantaneous auxiliary contacts
GV2 + GV3P
Frontbg
Left Hand Side
1
2
N.O. + N.C.
N.O. + N.O.
N.O. + N.C.
N.O. + N.O.
10
1
1
1
Fault signaling contact +
instantaneous auxiliary contact
GV2 + GV3P
Left Hand Sided
1
N.O. (fault) + N.O.
N.O. (fault) + N.C.
N.C. (fault) + N.O.
N.C. (fault) + N.C.
1
1
1
1
Short circuit signaling contact
GV2 + GV3P
Left Hand Side
1
SPDT
1
b Mounting of a GVAE contact block or a GV2AK00 visible isolation block on GV2P.
c Choice of N.C. or N.O. contact operation, depending on which way the reversible block is mounted.
d The GVAD is always mounted next to the starter.
e For spring terminals add 3 to the catalog number. Example: GVAE113
f One trip or one fault signaling can be fitted per GV3.
g Cannot be used with GV2GH7 insulator.
Catalog Number
GVAE1
GVAE11e
GVAE20e
GVAN11e
GVAN20e
GVAD1010
GVAD1001
GVAD0110
GVAD0101
GVAM11
$ Price
21.80
35.70
35.70
35.70
35.70
54.00
54.00
54.00
54.00
35.70
Table 18.128: Voltage Trips–Technical Data (GV2AU, GV2AS)
GVAD0101
Rated Voltage–660 Vac
Model
Inrush
Sealed
Pick-Up Voltage
GVAU
12 VA / 8 W
3.5 VA / 1.1 W
0.8 to 1.1
GVAS
14 VA / 10.5 W
5 VA / 1.6 W
0.7 to 1.1
h From the loss of voltage at the trip terminals to the opening of the starter contacts.
Table 18.129: GV3P Accessories New!
Drop-Out Voltage
0.35 to 0.7
0.2 to 0.75
Operating Timeh
10 to 15 ms
10 to 15 ms
Description
Set of 3-pole 115 A busbars
(tap-offs: 2, pitch: 64 mm)
Set of 3-pole 115 A busbars
(tap-offs: 3, pitch: 64 mm)
Cover “Larger Spacing” UL 508 type E
(Only one cover required on supply side)
IP 20 cover
(Two covers required per starter)
Padlocking device
For use with up to 4 padlocks (not supplied)
Ø 6 mm shank maximum
For GV3P
GV3P••
GV3P••
GV3P••
GV3P••
GV3P••
GV3P•••
Catalog Number
GV3G264
GV3G364
GV3G66
LAD96570
GV2V03
$ Price
25.00
45.00
18.00
12.00
15.00
GVAN11
18-34
CP10
I11
Discount
Schedule
© 2009 Schneider Electric
All Rights Reserved
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Page 2

Starters Accessories
TeSys® Manual Starters and Protectors LS1 Fuseholders
Refer to Catalog 2502CT0001 wwww.wDwa.tsacShhneeeidt4erU-e.cleocmtric.us
45 mm wide (same dimensions as GV2ME)
Available with screw clamp and spring type terminals
Mounts directly to LC1D09–D32 contactors (with use of GV2AF3 or GV2AF4)
Meets application needs for fusible starter
Uses GV2AE instantaneous contact blocks to open control circuits
DIN rail mounted
LS1D30
Table 18.133:
Description
Fuse Type
Dimensions
IN mm
Spring terminals, 3-pole
Screw clamp terminals, 3-pole
CC, KTK-R
CC, KTK-R
0.41 x 1.5
0.41 x 1.5
10.3 x 38
10.3 x 38
Spring terminals, 3-pole
aM, gG
0.39 x 1.5
10 x 38
Screw clamp terminals, 3-pole
aM, gG
0.39 x 1.5
10 x 38
Auxiliary main pole adder
aM, gG
0.39 x 1.5
10 x 38
a Can be mounted on left-hand or right-hand side of the 3-pole LS1D32 block.
Use In
US Markets
US Markets
European Markets
European Markets
European Markets
Catalog Number
LS1D303
LS1D30
LS1D323
LS1D32
LA8D324a
$ Price
86.
86.
101.
86.
65.
Table 18.134: Specifications
Type
Max. voltage
Max. current
Conforming to standards
Product approvals
Protective treatment
Ambient air temperature
—operation
Wiring
Number of conductors and cross sectional area (c.s.a.)
Solid cable
Flexible cable without cable end
Flexible cable with cable end
Resistance to mechanical impact conforming to IEC 60947-1 §7-1-6
Tightening torque
Sensitivity to phase failure
LS1D30, LS1D303
LS1D32, LS1D323, LS1DT32
600 V 3 Phase
30 A
IEC 60947-1, 60947-2, 60947-4-1, EN60204, BS4841, UL 508,
CSA 222.2 No. 14, NFC 63-650, 63-120, 79-130, VDE 0113, 0660
UL, CSA
BV
“TH”
-58 to 158o F
(-50 to +70o C)
“TH”
Max.
2–#8 AWG (2–6 mm2)
2–#8 AWG (2–6 mm2)
2–#10 AWG (2–4 mm2)
0.5 J
15 in-lb (1.7 N•m)
No
Min.
2–#16 (2–1 mm2)
2–#14 (2–1 mm2)
2–#16 AWB (2–1 mm2)
Table 18.135: Specifications
Operating Positions:
30 30
File E164864
CNN NLRV
File LR81630
Class 3211 05
Rated voltage—600 V
Rated thermal current—25 A (GV2), 63 A (GV3)
Mechanical life:
GV2:
100,000 operations
Shock resistance—30 g (conforming to IEC 600 68-2-27)
Vibration resistance—5 g (5 to 150 Hz) (IEC 600 68-2-26)
Ambient temperature:
-40 to 176oF (-40 to +80oC) for storage
-4 to 140oF (-20 to +60oC) open operation
-4 to 104oF (-20 to +40oC) enclosed operation
Maximum operating life—25 operations per hour
Operating current of magnetic trip is approximately 13 times maximum
thermal trip (non-adjustable setting)
18-36
I11
Discount
Schedule
© 2009 Schneider Electric
All Rights Reserved
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Page 3

www.schneider-electric.us
GV2GH7
LAD31
LAD311
Starters Accessories
TeSys® GV2 Manual Starters and Protectors
Refewr wtowC.DaatataloShge2et540U2.cComT0001
Table 18.136: GV2 Mounting Accessories
Description
Common mounting plate
Adapter plate
Combination block
7.5 mm compensation plate
Mounting plate
Application
For GV2 plus any 3-pole LC1D09 thru LC1D25 contactor.
(supplied with GV1G02 connector)
For screw mounting of GV2M
Interconnect for GV2 plus any 3-pole LC1K or LP1K contactor
Interconnect GV2 and LC1D09 thru D32
Interconnect GV2 and LC1D09 thru D32 mounted on LAD31
To allow mounting of GV2M and GV2P on a common bus bar
For mounting GV2ME or GV2P and contactor LC1D09 thru D32
Standard
Pack b
Catalog Number
1 GK2AF01
10 GV2AF02
10 GV2AF01
10 GV2AF3
10 GV2AF4
10 GV1F03
10 LAD31
10 LAD311
Table 18.137: GV2 Cabling Accessories—Bus Bars
Description
3-Pole, 63 A Bus Bar
Application
For feeding 2 GV2 starters
For feeding 3 GV2 starters
For feeding 4 GV2 starters
For feeding 5 GV2 starters
Pitch
45
54
72
45
54
45
54
72
54
Standard Pack b
1
1
1
1
1
1
1
1
1
Catalog Number
GV2G245
GV2G254
GV2G272
GV2G345
GV2G354
GV2G445
GV2G454
GV2G472
GV2G554
Table 18.138: GV2 Other Cabling Accessories
Description
Application
Terminal blocks
Top feed for use with bus bars
Bottom feed, to be used with bus bars; can be fitted with GV1L3
current limiter
Protective end cover
To cover unused bus bar outlets
3-pole flexible connector
For connecting a GV2 to an LC1D09 thru D25 contactor
Conduit adapter (12" NPT)
Incoming line insulator
For GV2P when used in UL 508 Type E applicationsa
a Cannot be used with front-mounted auxiliary contact block.
Standard Pack b Catalog Number
1 GV1G09
1 GV2G05
5 GV1G10
10 GV1G02
1 GV2AK1
10 GV2GH7
Table 18.139: GV2 Other Accessories
Description
Visible isolation block - GV2P
Current limiter - GV2M
Through-Door operator - GV2P
Application
Front mount, 3-pole visible isolation on incoming side of GV2P
Increases interrupt capacity when attached to GV2M
For operating GV2P through enclosure door (red handle, yellow
legend plate) For NEMA 1 use. IP54
Standard Pack b Catalog Number
1 GV2AK00
1 GV1L3
1 GV2AP02
Table 18.140: GV2 Enclosures
Description
Mounting
Enclosures for GV2M
Surface mount
with or without accessories
(maximum of 1 accessory
Flush mount
on right and left)
Enclosures are not UL or CSA listed. Flush mount reduced width
(max. of 1 accessory on right)
Rating
NEMA 1, IP41
IP55
NEMA 1, IP41
IP55
NEMA 1, IP41
IP55
Catalog Number
GV2MC01
GV2MC02
GV2MP01
GV2MP02
GV2MP03
GV2MP04
Table 18.141: GV2 Enclosures Accessories
Description
Type
Padlocking device for GV2M (when
padlocked, starter is automatically in Off
position)
Spring return
Mushroom head stop push button
(40 mm, red) c
Latching
Key release (Ronis key no. 455)
Turn to Release
Latching / Padlockable Turn to Release
Sealing kit
For enclosures GV2MC01 and GV2MP01
110 V
110 V
110 V
110 V
Green
Red
Orange
White
Pilot Light (neon)
220/240 V
220/240 V
220/240 V
220/240 V
Green
Red
Orange
White
380/440 V
380/440 V
380/440 V
380/440 V
b Orders must specify multiples of quantities listed.
c Supplied with IP55 sealing kit.
Green
Red
Orange
White
Standard Packb Catalog Number
1 GV2V01
1 GV2K011
1 GV2K021
1 GV2K031
1 GV2K04
10 GV2E01
10 GV2SN13
10 GV2SN14
10 GV2SN15
10 GV2SN17
10 GV2SN23
10 GV2SN24
10 GV2SN25
10 GV2SN27
10 GV2SN33
10 GV2SN34
10 GV2SN35
10 GV2SN37
$ Price Each
21.60
7.10
14.0
3.20
3.20
5.40
6.20
12.30
$ Price Each
23.30
23.30
23.30
28.70
28.70
34.20
34.20
34.20
34.20
$ Price Each
34.20
34.20
3.60
14.30
16.20
15.00
$ Price Each
71.40
117.00
135.00
$ Price Each
54.00
78.00
31.10
54.00
27.90
49.70
$ Price Each
26.90
35.90
104.00
52.00
117.00
18.00
26.90
GV2AF3 / GV2AF4
© 2009 Schneider Electric
All Rights Reserved
I11
Discount
Schedule
18-37
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Page 4
Part Number GV2P32
Manufactur Steven Engineering
Description Manual Starter and Protector
Total Page 6 Pages
PDF Download
GV2P32 datasheet
Download PDF File
GV2P32 datasheet
View Html for PC & Mobile


Related Datasheet

GV2P32 ,

site map

webmaste! click here

contact us

Buy Components