Description
The AHE Series of DC/DC converters feature high
power density and an extended temperature range for
use in military and industrial applications. Designed to
MIL-STD-704D input requirements, these devices have
nominal 28VDC inputs with ±5V, ±12V and ±15V dual
outputs to satisfy a wide range of requirements. The
circuit design incorporates a pulse width modulated
push-pull topology operating in the feed-forward mode
at a nominal switching frequency of 250KHz. Input to
output isolation is achieved through the use of
transformers in the forward and feedback circuits.
The advanced feedback design provides fast loop
response for superior line and load transient characteristics
and offers greater reliability and radiation tolerance
than devices incorporating optical feedback circuits.
Manufactured in a facility fully qualified to MIL-PRF-
38534, these converters are fabricated utilizing DSCC
qualified processes. For available screening options,
refer to device screening table in the data sheet.
Variations in electrical, mechanical and screening can
be accommodated. Contact IR Santa Clara for special
requirements.
AHE
Features
n 17V to 40VDC Input Range
n 28VDC Nominal Input
n ± 5V, ±12V and ±15V Outputs Available
n Indefinite Short Circuit and Overload
Protection
n 12.9W/in3 Power Density
n 15W Output Power
n Fast Loop Response for Superior Transient
Characteristics
n Operating Temperature Range from -55°C to
+125°C Available
n Popular Industry Standard Pin-Out
n Resistance Seam Welded Case for Superior
Long Term Hermeticity
n Efficiencies up to 82%
n Shutdown from External Signal
n Military Screening
n 314,000 hour MTBF at 85°C (AUC)
n Standard Microcircuit Drawings Available
www.irf.com
www.DataSheet4U.net
1
01/08/07



International Rectifier Electronic Components Datasheet

AHE28xxD Datasheet

HYBRID-HIGH RELIABILITY DC/DC CONVERTER

No Preview Available !

AHE28xxD pdf
AHE28XXD Series
Specifications
Absolute Maximum Ratings
Input voltage
Soldering temperature
Operating case temperature
Storage case temperature
-0.5V to +50VDC
300°C for 10 seconds
-55°C to +125°C
-65°C to +135°C
AHE2805D
Table I. Electrical Performance Characteristics
Test
Symbol
Conditions
-55°C Tc +125°C
Vin = 28 Vdc ±5%, CL = 0
Unless otherwise specified
Output voltage
Output current 9, 11
Output ripple voltage 8, 9
Output power 4, 9, 11
Line 9
Regulation 10
Load
Regulation 9
Input current
Input ripple current 8
Efficiency
Isolation
Capacitive load 6, 12
Power dissipation
load fault
Switching frequency 9
VOUT
IOUT
VRIP
POUT
VRLINE
VRLOAD
IIN
IRIP
EFF
ISO
CL
PD
FS
IOUT = 0
VIN = 17, 28, and 40 V dc
VIN = 17, 28, and 40 V dc,
B.W. = DC to 2MHz
VIN =17,28, and 40 V dc
VIN = 17, 28, and 40 V dc,
Iout = 0, ±313, and ±625mA
VIN = 17, 28, and 40 V dc,
IOUT = 0, ±313,and ±625
mA
IOUT = 0, inhibit (pin 2)
tied to input return (pin 10)
IOUT = 0,
inhibit (pin 2) = open
IOUT = ±625mA
B.W. = DC to 2MHz
IOUT = ±625mA
TC = +25°C
Input to output or any pin
to case (except pin 8)
at 500V dc Tc = +25ºC
No effect on dc
performance,
Tc = +25ºC
Overload, TC = +25°C 3
Short circuit, TC = +25°C
IOUT = ±625mA
Output response to step
transient load changes 7
VOTLOAD 50% load to/from100%load
No load to/from 50% load
Group A
Subgroups
1
2,3
1,2,3
1,2,3
1,2,3
1
2,3
1,2,3
1,2,3
1,2,3
1
1
4
1
1
4,5,6
4
5,6
4
5,6
Device
Types
All
All
All
All
All
All
All
All
All
All
All
All
01
02
03
All
All
Limits
Min
±4.95
±4.90
0.0
15
Max
±5.05
±5.10
±625
60
25
50
110
18
40
50
80
100
200
225
225
250
-300
-450
-500
-750
6.0
6.0
275
245
275
+300
+450
+500
+750
Unit
V
mA
mVp-p
W
mV
mV
mA
mAp-p
%
M
µF
W
KHz
mVpk
For Notes to Specifications, refer to page 3
2
www.irf.com



International Rectifier Electronic Components Datasheet

AHE28xxD Datasheet

HYBRID-HIGH RELIABILITY DC/DC CONVERTER

No Preview Available !

AHE28xxD pdf
AHE28XXD Series
Table I. Electrical Performance Characteristics - continued
Test
Symbol
Conditions
-55° Tc +125°C
Vin = 28 Vdc ±5%, CL= 0
unless otherwise
specified
Group A
Subgroups
Device
Types
Recovery time step
transient load
changes 1, 7
TTLOAD
Output response
transient step line
changes 5, 12
VOTLINE
Recovery time
transient step
line changes1, 5, 12
Turn on overshoot 9
Turn on delay 2, 9
Load fault recovery 12
TTLINE
VTonOS
TonD
TrLF
50% load to/from 100%
load
No load to 50% load
50% load to no load
Input step 17 to 40V dc
Input step 40 to 17V dc
Input step 17 to 40V dc
Input step 40 to 17V dc
IOUT = 0 and ±625mA
IOUT = 0 and ±625mA
4
5,6
4,5,6
4,5,6
4,5,6
4,5,6
4,5,6
4,5,6
4,5,6
4,5,6
4,5,6
All
All
All
All
All
All
All
All
All
All
Limits
AHE2805D
Unit
Min Max
70
100
1500
5.0
1200
µs
ms
mVpk
-1500
4.0
ms
4.0
600 mVpk
10 ms
10 ms
Notes to Specifications
1 Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±0.1 % of VOUT at 50 % load.
2 Turn on delay time measurement is for either a step application of power at the input or the removal of a ground signal from the
inhibit pin (pin 2) while power is applied to the input.
3 An overload is that condition with a load in excess of the rated load but less than that necessary to trigger the short circuit
protection and is the condition of maximum power dissipation.
4 Total power at both outputs. For operation at 16V dc input, derate output power by 33 %.
5 Input step transition time between 2.0µs and 10µs.
6 Capacitive load may be any value from 0 to the maximum limit without compromising dc performance. A capacitive load in excess
of the maximum limit will not disturb loop stability but may interfere with the operation of the load fault detection circuitry,
appearing as a short circuit during turn-on.
7 Load step transition time between 2.0µs and 10µs.
8 Bandwidth guaranteed by design. Tested for 20KHz to 2.0MHz.
9 Tested at each output.
10 When operating with unbalanced loads, at least 25 % of the load must be on the positive output to maintain regulation.
11 Parameter guaranteed by line and load regulation tests.
12 Parameter shall be tested as part of design characterization and after design or process changes. Thereafter parameters shall be
guaranteed to the limits specified in Table I.
www.irf.com
3




Part Number AHE28xxD
Description HYBRID-HIGH RELIABILITY DC/DC CONVERTER
Maker International Rectifier
Total Page 10 Pages
PDF Download
AHE28xxD pdf
Download PDF File
AHE28xxD pdf
View for Mobile






Related Datasheet

1 AHE28xxD HYBRID-HIGH RELIABILITY DC/DC CONVERTER International Rectifier
International Rectifier
AHE28xxD pdf
2 AHE28XXS HYBRID-HIGH RELIABILITY DC/DC CONVERTER IRF
IRF
AHE28XXS pdf
3 AHE28xxS ADVANCED ANALOG HYBRID-HIGH RELIABILITY DC/DC CONVERTERS International Rectifier
International Rectifier
AHE28xxS pdf




Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z

site map

webmaste! click here

contact us

Buy Components