HYBRID-HIGH RELIABILITY DC/DC CONVERTER

No Preview Available !

AFL12015D pdf
PD - 94463C
HYBRID-HIGH RELIABILITY
DC/DC CONVERTER
AFL120XXD SERIES
120V Input, Dual Output
Description
The AFL Series of DC/DC converters feature high power
density with no derating over the full military temperature
range. This series is offered as part of a complete family
of converters providing single and dual output voltages
and operating from nominal +28V or +270V inputs with
output power ranging from 80W to 120W. For applications
requiring higher output power, individual converters
can be operated in parallel. The internal current sharing
circuits assure equal current distribution among the
paralleled converters. This series incorporates International
Rectifier’s proprietary magnetic pulse feedback
technology providing optimum dynamic line and load
regulation response. This feedback system samples
the output voltage at the pulse width modulator fixed
clock frequency, nominally 550KHz. Multiple converters
can be synchronized to a system clock in the 500KHz
to 700KHz range or to the synchronization output of
one converter. Undervoltage lockout, primary and
secondary referenced inhibit, soft-start and load fault
protection are provided on all models.
These converters are hermetically packaged in two
enclosure variations, utilizing copper core pins to
minimize resistive DC losses. Three lead styles are
available, each fabricated with International Rectifier’s
rugged ceramic lead-to-package seal assuring long
term hermeticity in the most harsh environments.
AFL
Features
n 80V To 160V Input Range
n
n
±5V,
High
±12V, and ±15V
Power Density -
Outputs Available
up to 70W/in3
n Up To 100W Output Power
n Parallel Operation with Power Sharing
n Low Profile (0.380") Seam Welded Package
n Ceramic Feedthru Copper Core Pins
n High Efficiency - to 87%
n Full Military Temperature Range
n Continuous Short Circuit and Overload
Protection
n Output Voltage Trim
n Primary and Secondary Referenced
Inhibit Functions
n Line Rejection > 50dB - DC to 50KHz
n External Synchronization Port
n Fault Tolerant Design
n Single Output Versions Available
n Standard Microcircuit Drawings Available
Manufactured in a facility fully qualified to MIL-PRF-
38534, these converters are fabricated utilizing DSCC
qualified processes. For available screening options,
refer to device screening table in the data sheet.
Variations in electrical, mechanical and screening can
be accommodated. Contact IR Santa Clara for special
requirements.
www.irf.com
1
12/15/06
Free Datasheet http://www.Datasheet4U.com


International Rectifier Electronic Components Datasheet

AFL12015D Datasheet

HYBRID-HIGH RELIABILITY DC/DC CONVERTER

No Preview Available !

AFL12015D pdf
AFL120XXD Series
Specifications
Absolute Maximum Ratings
Input voltage
Soldering temperature
Operating case temperature
Storage case temperature
-0.5V to +180VDC
300°C for 10 seconds
-55°C to +125°C
-65°C to +135°C
Static Characteristics -55°C < TCASE < +125°C, 80V< VIN < 160V unless otherwise specified.
Parameter
Group A
Subgroups
Test Conditions
Min Nom Max Unit
INPUT VOLTAGE
OUTPUT VOLTAGE
AFL12005D
AFL12012D
AFL12015D
AFL12005D
AFL12012D
AFL12015D
OUTPUT CURRENT
OUTPUT POWER
AFL12005D
AFL12012D
AFL12015D
AFL12005D
AFL12012D
AFL12015D
MAXIMUM CAPACITIVE LOAD
OUTPUT VOLTAGE
TEMPERATURE COEFFICIENT
Note 6
80
120 160
V
VIN = 120 Volts, 100% Load
1 Positive Output
1 Negative Output
1 Positive Output
1 Negative Output
1 Positive Output
1 Negative Output
2, 3 Positive Output
2, 3 Negative Output
2, 3 Positive Output
2, 3 Negative Output
2, 3
2, 3
Positive Output
Negative Output
4.95
-5.05
11.88
-12.12
14.85
-15.15
4.90
-5.10
11.76
-12.24
14.70
-15.30
5.00
-5.00
12.00
-12.00
15.00
-15.00
5.05
-4.95
12.12
-11.88
15.15
-14.85
5.10
-4.90
12.24
-11.76
15.30
-14.70
V
VIN = 80, 120, 160 Volts - Notes 6, 11
Either Output
Either Output
12.8
6.4
A
Either Output
5.3
Total of Both Outputs. Notes 6,11
80
96 W
100
Each Output Note 1
10,000
µF
VIN = 120 Volts, 100% Load - Notes 1, 6
-0.015
+0.015 %/°C
OUTPUT VOLTAGE REGULATION
Line
Load
1, 2, 3
1, 2, 3
Note 10
No Load, 50% Load, 100% Load
VIN = 80, 120, 160 Volts.
-0.5
-1.0
+0.5
+1.0
Cross
AFL12005D
AFL12012D
AFL12015D
1, 2, 3
1, 2, 3
1, 2, 3
VIN = 80, 120, 160 Volts. Note 12
Positive Output
Negative Output
Positive Output
Negative Output
Positive Output
Negative Output
-1.0
-8.0
-1.0
-5.0
-1.0
-5.0
+1.0
+8.0
+1.0
+5.0
+1.0
+5.0
%
For Notes to Specifications, refer to page 4
2 www.irf.com
Free Datasheet http://www.Datasheet4U.com


Part Number AFL12015D
Description HYBRID-HIGH RELIABILITY DC/DC CONVERTER
Maker International Rectifier
Total Page 11 Pages
PDF Download
AFL12015D pdf
Download PDF File
AFL12015D pdf
View for Mobile



Buy Electronic Components




Related Datasheet

1 AFL12015D HYBRID-HIGH RELIABILITY DC/DC CONVERTER International Rectifier
International Rectifier
AFL12015D pdf
2 AFL12015D HYBRID-HIGH RELIABILITY DC/DC CONVERTER International Rectifier
International Rectifier
AFL12015D pdf
3 AFL12015S HIGH RELIABILITY HYBRID DC/DC CONVERTERS International Rectifier
International Rectifier
AFL12015S pdf
4 AFL12015S HIGH RELIABILITY HYBRID DC/DC CONVERTERS International Rectifier
International Rectifier
AFL12015S pdf
5 AFL12015S HIGH RELIABILITY HYBRID DC/DC CONVERTERS International Rectifier
International Rectifier
AFL12015S pdf
6 AFL12015S HIGH RELIABILITY HYBRID DC/DC CONVERTERS International Rectifier
International Rectifier
AFL12015S pdf






Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z

site map

webmaste! click here

contact us

Buy Components